Specifications

15
Threaded pipe
1. Apply pipe joint compound or Teflon
R
tape to all male pipe threads.
2. Tighten all threaded joints and make all solder connections.
IMPORTANT: Secure ground clamp to metal pipes.
CPVC plastic pipe
1. Clean, prime and cement all joints, following the manufacturer’s instructions supplied with the
plastic pipe and fittings.
Other
1. Follow the piping system manufacturers instructions when using other pipe approved for potable
water.
IMPORTANT: Secure ground clamp to metal pipes.
Install Valve Drain Hose
1. Measure, cut to needed length and connect the 3/8 drain line (provided) to the water softener
valve drain fitting. Use a hose clamp to hold the hose in place.
NOTE:
If codes require a rigid drain line see Valve Drain requireme nts” section.
2. Run the drain hose or copper tubing to the floor drain. Secure drain hose. This will prevent
whipping’ during regenerations. See Air Gap Requirements” section.
Install Salt Storage Tank Overflow Hose
1. Measure, c ut to needed length and connect the 3/8” drain line (provided) to the salt storage tank
overflow elbow a n d se cure in place with a hose clamp.
2. Run the hose to the floor drain, or other suitable drain point no higher than the drain fitting on the
salt storage tank. (This is a gravity drain.) If the tank overfills with water , the excess water flows
to the drain point. Cut the dra in line to the desired length and route neatly out of the w ay.
IMPORTANT: For proper oper ation of the water softener, do not connect the water softener
valve drain tubing to the salt storage tank overflow hose.
Te s t f o r L e a k s
To prevent air pressure in the water softener and plumbing system, do the following steps in order.
1. Fully open two or more softened cold water faucets close by the water softener, located
downstream from the water softener.
2. Place the single valve bypass valve or 3 valve bypass in “bypass” position. See Plan The
Installation section.
3. Fully open the main water supply valve. Run wa ter until there is a steady flow from the opened
faucets, with no air bubbles.
4. Place bypass valve(s) in “service or soft water position as follows:
Single valve bypass: Slowly move the valve stem towar d “service”, pausing several times
to allow the water softener to fill with water.
3 valve bypass: Fully close the bypass valve and open the outlet valve. Slowly open the
inlet valve, pausing several times to allow the water softener to fill with water.
5. After about three minutes, open a hot water faucet until the re is a steady flow and there are no air
bubbles, then close.
6. Close a ll cold water faucets and check for leaks at the plumbing connections that you made.