Specifications

PRESS TO SCHEDULE
HOLD TO START
PROGRAM
SET
SALT
LEVEL
RECHARGE
OPERATING (Steady)
LOW SALT (Flashing)
15
Programming the Water Softener
(Models WHES30 & WHES33)
FIG. 27
SET TIME OF DAY
If the words “CURRENT TIME" do not show in the
display, press the PROGRAM button until they do.
1. Press the r UP or s DOWN buttons to set the
present time. Up moves the display ahead; down
sets the time back. Be sure AM or PM is correct.
NOTE: Press buttons and quickly release to slowly
advance the display. Hold the buttons down
for fast advance.
SET WATER HARDNESS NUMBER
1. Press the PROGRAM button once again to display
a flashing “25” and the word “HARDNESS”.
Questions? Call Toll Free 1-866-986-3223 Monday- Friday, 8 AM - 7 PM EST
or visit www.ecodynewatertreatment.com
When you call, please be prepared to provide the model and serial number,
found on the rating decal, typically located on the rim below the salt lid hinges.
FIG. 26
STATUS LIGHT (Model WHES33 Only)
When the WHES33 water softener is connected to
electrical power, the status light on the control panel
will be on or flashing, as follows:
= Light flashing rapidly, with “CURRENT TIME”
shown in the display and the clock flashing
slowly - The present time needs to be set, either
during initial start up or after a long power outage.
See “Set Time of Day”, at right.
= Light flashing slowly, along with the salt level
indicators in the display - The salt monitor sys-
tem indicates a low salt level and needs to be set.
See “Set Salt Level” on Page 17.
= Light flashing rapidly, with “Err” shown in the
display - The electronic self-diagnostics have
detected a problem. See “Troubleshooting” on
Page 22.
= Light on steady (not flashing) - The system has
power applied and does not require any attention.
PROGRAM THE SOFTENER
When the transformer is plugged into the electrical
outlet, the model code (“LE31” fro Model WHES30 or
“LE33” for Model WHES33) and a test number (exam-
ple: J3.0), are briefly shown in the display. Then the
words “CURRENT TIME” appear and 12:00 PM
begins to flash.
FIG. 28
continued on next page
UP button
Display
SET SALT LEVEL
button
PROGRAM button
DOWN button
RECHARGE button
STATUS LIGHT
(see below)