Regeneration (Start) Time
Starting at the 2:00AM regeneration start time, the softener begins regenerations, ending
approximately at 4:00AM. This is a good time in most households because water is not in use (see
Automatic Bypass section). If a different time would be better for your needs, do the steps below to
change the starting time.
1. Press and hold in the
PROGRAM button until “RECHARGE TIME” shows steady in the
display and 2:00 AM begins to flash.
AM
RECHARGE
TIME
2. Press the Up or Down button to display the desired start time. The up button moves the
time ahead; the down button moves the time back. Press the PROGRAM button to select time. If
no more settings need to be changed, press the PROGRAM button until the display returns to the
present time of day.
Maximum Days Between Regenerations
The default setting allows the timer to control regeneration frequency based on water usage readings
from the water meter. It provides the most economical operation. You can set a maximum time (in days)
between regenerations. For example, no more than 3 days will pass without a regeneration occurring
if you set dY 3 in the display. 1 to 7 days ar e available settings. To make a change from the default
setting follow the steps below.
1. Press and hold in the
PROGRAM button until the Regeneration (Start) Time screen begins
to fla sh. Press the PROGRAM button once more to move to the Maximum Days Between
Regenerations screen. dY -- will flash on the display, with RECHARGE remaining steady.
RECHARGE
2. Pressing the Up button will increase the number of days, the Down button will decrease
the number of days. Press the PROGRAM button to select the number of days. If no more settings
need to be changed, press the PROGRAM button until the display returns to the present time of
day.
IMPORTANT: Initiating this option may reduce the efficiencies and increase salt usage of this