Whirlpool AUTOMATIC ICE CUBE MAKER User’s Instructions & Care and Cleaning Guide MODELS CH E-5R CHS-5R CHE-7R CHS-7R Part No. 585102 Rev.
General Information The machine produces clear hard ice by circulating water over a freezing plate. As the water freezes into ice, minerals in the water are constantly being rejected and a clear sheet of ice is formed. When the desired thickness is reached, the ice sheets are released and slide onto a cutter grid where the sheet is divided into individual cubes. At the end of each freezing cycle the water containing the rejected minerals is discharged to the drain.
13 Remove the top water distributor tube. Remove the two wing nuts which hold the distributor tube in position on the top freezing plate. Pull out the water pump hose from the right end of the distributor. Pull out the rubber plug from the left end of the distributor. A stiff bristled brush of approximately the same diameter as the distributor will facilitate removal of scale accumulation. 14. Remove the ice cube deflectors between each cutter grid.
18. Wash the ice maker interior with a mild solution of detergent and rinse with fresh water. Then wipe the ice maker interior with the sanitizer solution (see item 1). 19. Reinstall distributors. grids, mercury switch, deflectors and NOTE: Mercury switches are to be positioned as indicated on the sketch located on the support rail. Incorrect position will result in malfunction of the machine. 16. Remove the water reservoir pan. Remove the syphon hose connected to the bottom of the pan.
All components of the ice maker are lubricated factory and should not require any additional oiling normal life of the machine. at the for the Cleaning and sanitizing are qualified service representative time should make subsequent the operator wishes to take machrne maintenance. Follow this procedure clean and sanitary: Periodic ice cube sanitary dealer is inspection and cleaning is necessary to keep your maker operating at peak efficiency and to assure a ice producing mechanism.
Check the following A. before calling C. a serviceman: runs but produces 1. Make sure service switch 2. Check fuses in power and remote refrigeration is positioned supply unit. to “on”. to ice maker Unit 1. 2. runs but produces Check would D. Check all mercury switches positioned over water trough. Arms must be vertical. If switch arms are not vertical, check for bind. Check position of switch capsule in bracket against sketch on support rail. for Whirlpool IOR~CCA~lON one Vacuum 2.