Installation Instructions
7
Make Electrical Connection
This oven is manufactured with a neutral (white) power supply 
wire and a cabinet-connected green (or bare) ground wire 
twisted together.
1.  Disconnect power.
2.  Feed the flexible conduit from the oven through the opening 
in the cabinet.
3.  Remove junction box cover, if it is present.
4.  Install a UL Listed or CSA Approved conduit connector to 
the junction box.
5.  Route the flexible conduit from the oven to the junction box 
through a UL Listed or CSA Approved conduit connector.
6.  Tighten screws on conduit connector.
7.  See the “Electrical Connection Options Chart” to complete 
installation for your type of electrical connection.
Electrical Connection Options Chart
4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply 
in the U.S. where local codes do not allow grounding through 
neutral, New Branch circuit installations (1996 NEC), mobile 
homes and recreational vehicles, new construction and in 
Canada.
1.  Connect the two black wires (B) together using a UL Listed 
wire connector.
2.  Connect the two red wires (C) together using a UL Listed 
wire connector.
3.  Untwist white wire from green (or bare) ground wire coming 
from the oven.
4.  Connect the two white wires (F) together using a UL Listed 
wire connector.
5.  Connect the green (or bare) ground wire (H) from the oven 
cable to the green (or bare) ground wire (in the junction box) 
using a UL Listed wire connector.
6.  Install junction box cover.
3-Wire Cable from Home Power Supply: U.S. Only
IMPORTANT: Use the 3-wire cable from home power supply 
where local codes permit a 3-wire connection.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
A.  UL listed or CSA approved conduit connector
A
If your home has: Go to section:
4-Wire 4-Wire Cable from Home 
Power Supply
3-Wire 3-Wire Cable from Home 
Power Supply
1/2"
(13 mm)
1/2"
(13 mm)
A.  Cable from home power supply
B.  Black wires
C. Red wires
D.  4-wire flexible conduit from 
oven
E.  Junction box
F.  White wires
G. UL listed wire connectors
H. Green (or bare) ground wires
I.  UL Listed or CSA Approved
  conduit connector
A
D
F
H
B
C
E
G
I
A.  Cable from home power
 supply
B.  Junction box
C. Black wires
D.  White wires
E.  Green (or bare) ground wire
  (from oven)
F.  4-wire flexible conduit from
 oven
G. Red wires
H. UL Listed wire connectors
I.  UL Listed or CSA Approved
  conduit connector
B
C
D
E
F
H
G
A
I