Code Description Explanation and Recommended Procedure
F1E5 Microwave Oven
Inverter Error
NOTE: Before starng any test, cycle power to the oven (power o, wait 10 seconds, then power
on). Aer powering on, be sure that a load, such as a microwave-safe cup of water, is present in
the microwave oven cavity, and start a microwave cooking funcon. Wait
1 minute, then verify that the failure happens again.
1. Make sure that all interlock switches works properly: when door is open, microwave light is
on, and door is closed, microwave light is o.
2. Unplug microwave oven or disconnect power.
3. Check the following on the Microwave ACU:
a. Relay 4903
b. Connector P8
4. Check the following connecons on the Inverter board:
a. CN701
b. CN702
c. CN703
5. If the door works properly and all connecons are okay, replace the Microwave Inverter
Board.
6. Reassemble all parts and panels before operang.
7. Plug in microwave oven or reconnect power.
8. To check if the error code is sll present, be sure that a load, such as a microwave-safe cup of
water, is present in the microwave oven cavity,and start a cooking funcon in the microwave
oven. Wait 1 minute to check if the error appears. If error remains, then go to Step 9. If not,
go to Step 17.
9. Unplug the oven or disconnect power.
10. Replace the Magnetron.
11. Reassemble all parts and panels before operang.
12. Plug in microwave oven or reconnect power.
13. To check if the error code is sll present, be sure that a load, such as a microwave-safe cup of
water, is present in the microwave oven cavity,and start a cooking funcon in the microwave
oven. Wait 1 minute to check if the error appears. If error remains, then go to Step 14. If not,
go to Step 17.
14. Unplug microwave oven or disconnect power and replace the Microwave ACU.
15. Reassemble all parts and panels before operang.
16. Plug in the oven or reconnect power and follow the on-screen prompts for a model
selecon.
17. Verify operaon is normal. Enter Diagnoscs mode, select “Error Diagnoscs”, and clear the
history. If the HMI-Central/UI board Control Panel Assembly was replaced, there is no need
to clear the error history.
Magnetron
MW Inverter
PWM
To
MW
Relay
4903
P8
WH
P354
BU
CN701
E701
1
2
3
CN703
CN702
RD RD
YL/
GN
3
2
1
P355