Code Description Explanation and Recommended Procedure
F1 E1 Internal oven appliance
manager error
NOTE: Before starng any test, cycle power to the oven (power o, wait 10
seconds, and power on).
PROCEDURE: Before proceeding, verify the error code by entering the Diagnoscs
mode and selecng “Error Diagnoscs”.
NOTE: If other error codes are stored, troubleshoot those other error codes rst.
1. Unplug the oven or disconnect power.
2. For single ovens: Replace the Copernicus ACU.
For double ovens: Replace both Copernicus ACU’s.
3. Reassemble all parts and panels before operang.
4. Plug in the oven or reconnect power.
5. If error persists aer Copernicus ACU is replaced, unplug the oven or
disconnect power, and then go to Step 6. If not, go to Step 9.
6. Replace HMI-Central/UI board Control Panel Assembly.
7. Reassemble parts and panels before operang.
8. Plug in the oven or reconnect power. Follow the on-screen prompts for a
model selecon.
9. Verify operaon is normal. Enter Diagnoscs mode, select “Error Diagnoscs”,
and clear the history. If the HMI-Central/UI board Control Panel Assembly was
replaced, there is no need to clear the error history.
F2 Keypad E0 Keypad disconnected NOTE: Before starng any test, cycle power to the oven (power o, wait 10
seconds, and power on).
PROCEDURE: Before proceeding, verify the error code by entering the Diagnoscs
mode and selecng “Error Diagnoscs”.
1. Unplug the oven or disconnect power.
2. Check that connectors J1 are rmly connected. If they are not, go to Step 3. If
they are, go to Step 6.
3. Reconnect any loose connectors.
4. Reassemble all parts and panels before operang.
5. Plug in the oven or reconnect power. If the failure is gone, go to Step 9. If the
failure is sll present, unplug the oven or disconnect power.
6. Replace the HMI-Central/UI board Control Panel Assembly.
7. Reassemble all parts and panels before operang.
8. Follow the on-screen prompts to select a model number.
9. Verify operaon is normal. Enter the Diagnoscs Menu, select “Error
Diagnoscs” and clear the history. If the Control Panel Assembly was replaced,
there is no need to clear the error history.
F2 Keypad E1 Stuck/shorted key
Speaker
KeypadUser Interface J1
Ribbon Cable
Control Panel Assembly