Code Description Explanation and Recommended Procedure
F9 E0 Product not wired correctly NOTE: Before starng any test, cycle power to the oven (power o, wait
10 seconds, and power on).
PROCEDURE: Before proceeding, verify the error code by entering the Diagnoscs
mode and selecng “Error Diagnoscs”.
1. Unplug the oven or disconnect power.
2. Access the electrical wiring from the house power supply to the oven.
3. Check house wiring to the product. Check to see if the neutral connecon is
switched with L1 or L2 (refer to the Installaon Instrucons for product wiring).
4. Verify correct power supply to unit L1 to L2 = 240 V, L1 to Neutral = 120 V and
L2 to Neutral = 120 V.
5. Reassemble all parts and panels before operang.
6. Plug in the oven or reconnect power.
7. Verify operaon is normal by running a cooking funcon. Enter Diagnoscs
mode, select “Error Diagnoscs”, and clear the history.