Installation Instructions
4
Electrical Requirements
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrical installer determine that
the ground path and the wire gauge are in accordance with local
codes.
Check with a qualied electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code,
ANSI/NFPA 70 – latest edition or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2 No. O-M91 – latest
edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection
To properly install your oven, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
■ Oven must be connected to the proper electrical voltage and
frequency as specied on the model/serial/rating plate. The
model/serial/rating plate is located under the control panel
on single ovens. See the following illustrations.
■ Models rated from 7.3 to 9.6 kW at 240 V (5.4 to 7.4 kW
at 208 V) require a separate 40 A circuit. Models rated at
4.8kW and below at 240 V (3.6 kW and below at 208 V)
require a separate 20 A circuit.
■ A circuit breaker is recommended.
■ Connect directly to the circuit breaker box (or fused
disconnect) through exible, armored, or nonmetallic
sheathed, copper cable (with grounding wire). See the
“Make Electrical Connection” section.
■ Flexible conduit from the oven should be connected directly
to the junction box.
■ Fuse both sides of the line.
■ Do not cut the conduit. The length of conduit provided is for
serviceability of the oven.
■ A UL-listed or CSA-approved conduit connector must be
provided.
■ If the house has aluminum wiring, follow the procedure
below:
Connect the aluminum wiring using special connectors
and/or tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
For power requirements refer to the following table.
Voltage Load
240 VAC 3,800 W
208 VAC 2,900 W
240 VAC 16.0 A
208 VAC 14.0 A
Single oven
A. Model/serial/rating plate
A