Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.
Recessed installation area must provide complete
enclosure around the recessed portion of the oven.
Grounded electrical supply is required. See the
“Electrical Requirements” section.
Electrical supply junction box should be located 3" (7.6 cm)
above the cutout or 3" (7.6 cm) maximum below the support
surface when the oven is installed in a wall cabinet. A
1" (2.5 cm) minimum diameter hole should have been drilled
in the right rear or left rear corner of the upper or lower
support surface to pass the appliance cable through to the
junction box.
NOTE: For undercounter installation, it is recommended
that the junction box be located in the adjacent right or
left cabinet. If you are installing the junction box on rear
wall behind oven, it is recommended that the junction box
be recessed and located in the upper center of the cabinet.
Oven support surface must be solid, level, and flush
with bottom of cabinet cutout.
Floor must be able to support a single oven weight of 129 lbs
(59 kg) for 27" (68.6 cm) models or 154 lbs (70 kg) for 30"
(76.2 cm) models.
Floor must be able to support a double oven weight of
251 lbs (114 kg) for 27" (68.6 cm) models or 288 lbs (131 kg)
for 30" (76.2 cm) models.
IMPORTANT: To avoid damage to your cabinets, check
with your builder or cabinet supplier to make sure that the
materials used will not discolor, delaminate, or sustain other
damage. This oven has been designed in accordance with
the requirements of UL and CSA International and complies
with the maximum allowable wood cabinet temperatures
of 194°F (90°C).
Undercounter Installation (with Cooktop Installed Above):
Refer to the Cutout Dimensions for Ovens Installed Under
Cooktop (separate sheet). See product website for list of
cooktop models approved for use above select wall-oven
models.
Product Dimensions — Single Ovens
B
C
D
E
A
G
F
27" (68.6 cm) models
A. 28
3
/
4
" (72.8 cm) max.
overall height
B. 25
7
/
16
" (64.6 cm) max.
recessed width
C. 26
3
/
4
" (67.9 cm)
recessed height
D. 23
1
/
4
" (59.1 cm) max.
recessed depth
E. 27" (68.6 cm) overall width
F. 12" (30.5 cm) from back
of control panel to start
of strain relief
G. 48" (121.9 cm) flexible
conduit length
30" (76.2 cm) models
A. 28
3
/
4
" (72.8 cm) max.
overall height
B. 28
1
/
2
" (72.4 cm) max.
recessed width
C. 26
3
/
4
" (67.9 cm)
recessed height
D. 23
1
/
4
" (59.1 cm) max.
recessed depth
E. 30" (76.2 cm) overall width
F. 12" (30.5 cm) from back
of control panel to start
of strain relief
G. 48" (121.9 cm) flexible
conduit length