Installation Instructions

4
1"
(25 mm)
0.25"
(5 mm)
1"
(25 mm)
1"
(25 mm)
1"
(25 mm)
Custom cabinet installation:
Recessed area or closet installation:
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum
carry-away capacity: 17 gal. (64 L) per minute. A 1/4" (6 mm)
diameter to 1" (25 mm) diameter Standpipe Adapter Kit is
available (Part Number 3363920). Top of standpipe must be at
least 30" (762 mm) high; install no higher than 96" (2.44 m) from
bottom of washer. If you have an overhead sewer and need to
pump higher than 96" (2.44 m), a sump pump and associated
hardware are needed. See “Alternate parts.”
Wall standpipe drain system
Laundry tub drain system
Minimum capacity: 20 gal. (76 L). Top of laundry tub must
be at least 30" (762 mm) above oor; install no higher than
96" (2.44 m) from bottom of washer.
4.5"
(114 mm)
4.5"
(114 mm)
See requirements for oor standpipe drain system.
30"
(762 mm)
min.
4.5"
(114 mm)
The drain system can be installed using a oor drain, wall
standpipe, oor standpipe, or laundry tub. Select the method
you need.
IMPORTANT: To avoid siphoning, only 4.5" (114 mm) of drain
hose should be inside standpipe. Always secure drain hose with
cable tie.
DRAIN SYSTEM
Floor standpipe drain system
0.25"
(5 mm)
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
1"
(25 mm)
1"
(25 mm)
1"
(25 mm)
39" min.
(990 mm)
1"
(25 mm)
27"
(686 mm)
1"
(25 mm)
Custom under-counter installation: