Service Manual
Table Of Contents
For Service Technician Use Only
DIAGNOSTICS
2-8
n
Whirlpool
®
, Maytag
®
, Amana
®
, & IKEA
®
Refrigerators
Step Step Code Component Acon Feedback
33
●
LED1
O
LED2
●
LED3
O
LED4
●
LED5
SANKYO
Ice maker
- Ice tray
thermistor
Entry: Display step number.
Do: Read the current temperature
of the ice maker tray, thermistor and
compare this value. This informaon
shall be dynamically updated every
second. Service user to monitor the
display feedback.
Exit: Clear feedback informaon.
NOTE: For models without twist tray
ice maker, the feedback will read as
open.
Open sensor display
●
LED6
O
LED7
O
LED8
O
LED9
O
LED10
Short sensor display
O
LED6
O
LED7
●
LED8
O
LED9
O
LED10
Pass test display
O
LED6
●
LED7
●
LED8
●
LED9
O
LED10
Sensor status blank unl gets a
valid reading
O
LED6
O
LED7
O
LED8
O
LED9
O
LED10
34 OFF NONE OFF OFF
35
●
LED1
●
LED2
●
LED3
●
LED4
●
LED5
Service
completed
Last step in service N/A
During the rst 30 seconds aer power up the product, press
TEMP seng buon, unl is located min posion, then hold the
refrigerator door switch to simulate the door is closed, and at
the same me hold press refrigerator TEMP buon for 5 seconds
unl the board enters service mode.
Into service state mode, all temperature LEDs turn on for and
turn OFF aer 10 seconds.
A user must use the SW1 buon to advance steps into service
mode. User shall wait 3 seconds between each keypress to allow
the system stabilizaon.
All sensors will be tested without required acon from service
personnel. This acon is taken aer the heater o.
Aer last step press SW1 to exit service mode, user interface will
reset to the last mode and start the power-up state.
Switch
Press
Display Informaon
Load
D 9 D 8 D 7 D 6
0
□ □ □ □
Start condion
1
□ □
Ƀ
□
Compressor On
2
□ □ □ □
Compressor O
3
□
Ƀ
□ □
Heater On
4
□ □ □ □
Heater O
5
Ƀ
□ □ □
Not Used
6
□ □ □ □
Display Fail Message
7
□
Ƀ
□ □
Return To Normal
OP (Default To Med)
The fail informaon is shown below with the LEDs turned ON,
this will appear in step 6 from the above table.
NOTE: If step 6 shows all LEDs blank means that board drivers
and sensors are working correctly.
D 6 (MIN
POSITION)
D 7
D 8
D 9
SW1
Ideal
Coldest
Replace
Water
Filter
Water Filter Reset
Hold 3 sec