Installation Instructions

23
The modular ice maker service sheet
Module Test Points
MODULE OHMMETER CHECKS
(NO POWER TO ICE MAKER AND
EJECTOR BLADES IN PARK)
TEST
POINTS
COMPONENT
MODULE
POSITION
OHMS
L-H MOLD HEATER
ATTACHED TO
SUPPORT
72
L-M MOTOR
DISCONNECT
FROM SUPPORT
8800
Service Procedures
COVER
PULL WATER ADJUSTMENT KNOB FIRST AND SNAP OFF
COVER. INDEX KNOB AND REINSTALL IN SAME POSITION
FOR WATER FILL.
MODULE, MOTOR, AND SUPPORT ASSEMBLY
INSERT PHILLIPS DRIVER IN ACCESS PORTS IN MODULE.
LOOSEN BOTH SCREWS. DISCONNECT SHUT-OFF ARM.
PULL MOLD FROM SUPPORT ASSEMBLY.
SHUT-OFF ARM
PULL OUT FROM SUPPORT. REINSERT TO FULL DEPTH.
MOLD AND HEATER
REMOVE MODULE, MOTOR, AND SUPPORT ASSEMBLY.
BIMETAL
REMOVE MODULE, MOTOR, AND SUPPORT ASSEMBLY.
PULL OUT RETAINING CLIPS WITH BIMETAL.
FILL CUP
REMOVE MODULE, MOTOR, AND SUPPORT ASSEMBLY.
REMOVE EJECTOR BLADES AND SHUT-OFF ARM. PULL
FILL CUP FROM MOLD.
EJECTOR BLADES OR STRIPPER
REMOVE MODULE, MOTOR, SUPPORT ASSEMBLY.
WHEN REINSTALLING EJECTOR BLADES, REALIGN “D”
COUPLING WITH MODEL CAM.
Specications
MOLD HEATER – 185 WATTS, 72 OHMS
THERMOSTAT – CLOSE 17° ± 3 °
(BIMETAL) OPEN 32° ± 3°
WATER FILL – 140CC, 7.5 SEC.
MOTOR – 1.5 WATTS, 8800 OHMS
MODULE – STAMPED CIRCUIT, PLUG-IN CONNECTORS
CYCLE – ONE REVOLUTION (EJECTS AND WATER FILL)
FOR 120 VOLT MODEL
Water level adjustment
TURNING THE SCREW CLOCKWISE DECREASES THE WATER
FILL.
1/2 TURN EQUALS 20CC OR 1.2 SEC.
FULL TURN EQUALS 40CC OR 2.4 SEC.
MAXIMUM ADJUSTMENT IS ONE FULL TURN EITHER
DIRECTION. ADDITIONAL ROTATION COULD DAMAGE
MODULE.
Removal
screws (3)
N
M
H
T
L
V
Shut-off arm
Adjustment screw
Mold attachment
screw access ports (2)
(Phillips)