Owner's Manual

Height dimensions are shown with the leveling legs
extended to the minimum height.
NOTE: When leveling legs are fully extended, add 5/8”
(1.6 cm) to the height dimensions.
Location Requirements
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from Beverage Center.
Failure to do so can result in death, explosion, or
fire.
4
INSTALLATION INSTRUCTIONS
IMPORTANT: This appliance is intended to be used in
household and similar applications such as:
Staff kitchen areas in shops, offi ce and other working
environments;
Farm houses and by clients in hotels, motels and other
residential type environments;
Bed and breakfast type environments;
Catering and similar non-retail applications.
To ensure proper ventilation for your Beverage Center, allow
for a 1/4” (6.35 mm) space on each side and at the top.
When installing your Beverage Center next to a fixed wall,
leave 2.1/2” (6.35 cm) minimum clearance on the hinge
side to allow for the door to swing open.
NOTE: It is recommended that you do not install the
Beverage Center near an oven, radiator, or other heat
source. Do not install
in a location where the
temperature will fall
below 55 °F (13 °C).
For best performance,
do not block the base
grille.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Opening Dimensions
1/4” (6.35 mm)
2.1/2” (6.35 cm)
14.3/4”
(37.5 cm)
A
1/2”
(1.3 cm)
24”
(60.96 cm) min.
B
24” (60.96 cm) min.
34.3/8” (87.3 cm) min.
35” (88.9 cm) max.
Critical dimensions:
A. 14.3/4” (37.5 cm) utility opening
B. 24” (60.96 cm) minimum opening width
Electrical Requirements
Before you move your Beverage Center into its final
location, it is important to make sure you have the proper
electrical connection.
A 115 Volt, 60 Hz., AC only, 15- or 20-amp fused,
grounded electrical supply is required. It is recommended
that a separate circuit serving only your Beverage Center
be provided. Use an outlet that cannot be turned off by a
switch. Do not use an extension cord.
NOTE: Before performing any type of installation, or
cleaning, unplug Beverage Center or disconnect power.
Recommended grounding method
If the floor of the opening is not level with the kitchen floor,
shim the opening to make it level with the kitchen floor.