30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNT CANOPY RANGE HOOD For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca HOTTE DE CUISINIERE A MONTAGE MURAL DE 30" ET 36" (76,2 ET 91,4 CM) Au Canada, pour assistance, installation ou service, composer le 1-800-807-6777 ou visiter notre site Web a www.whirlpool.
TABLE OF CONTENTS TABLE DES MATIERES RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS. 4 TOOIS AN Parts... sees ceecseesseeeeceeeeaeenaeeseeeeceeaneaeesaeneeentaeernetens 4 SECURITE DE LA HOTTE DE CUISINIERE ..........:s00cecse0 EXIGENCES D’INSTALLATION Outils @t PIECES... ee eee ene ete eeeeteeeeneteeceeseetaesnaeesennenenenteaees 15 17 17 Location Requirements... eeceeeeeeeneeeseseeeteeteaeteeeenesnnereneeetee 4 Venting Requirements ..0....
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: m Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. mw Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Level installer’s responsibility to comply with installation clearances specified on the model/serial/rating plate. The model/serial/ rating plate is located behind the left filter on the rear wall of the vent hood. Drill with 11/4" (3.2 cm), */e" (38.
The chimneys can be adjusted for different ceiling heights. See the following chart. Vented Installations *9714" (68.9 cm) min. **41%" (104.5 cm) max. z Co el *27%6" (68.9 cm) min. *45%2" (115.6 cm) max. 173s" (43.7 om) Y Min. ceiling height Max. ceiling height Electric cooking surface 7' 4" (2.23 m) 9' 5" (2.87 m) Gas cooking surface 7' 7* (2.31 m) 9' 5" (2.
Makeup Air Example Vent System Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in 90° elbow <— Wail cap 6 ft (1.8 m)—>| O your area. 2 ft (0.6 m) Venting Methods This canopy hood is factory set for venting through the roof or wall. A 6" (15.2 cm) round vent system is needed for installation (not included).
INSTALLATION INSTRUCTIONS a before hood is installed. It is recommended that the vent system be installed 5. For wood, drill /16" (4.8 mm) pilot holes at all locations where screws are being installed into wood. Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent. For wall anchors, drill 7/16" (10 mm) holes at all locations where wall anchors are being used.
Install In-Line Smart Kit - Optional For vented installations only: 1. Fit vent system over the exhaust outlet. NOTE: Your range hood can work with either an internal or an inline (external) blower motor system. An optional In-Line Smart 2. 3. Seal connection with clamps. Check that back draft dampers work properly. Kit (purchased separately) allows the blower motor that comes F inside the range hood cavity. 1.
6. Use UL listed wire connectors and connect white wires (E) together. ae a Electrical Shock Hazard Electrical Shock Hazard Disconnect power before servicing. Electrically ground blower. Replace all parts and panels before operating. ; . : Connect ground wire to green and yellow ground wire in terminal box. Failure to do so can result in death or electrical shock. 1. Disconnect power. 2. Remove terminal box cover. 3. Remove the knockout in the terminal box and install .
2. Secure the bottom of the duct with (2) 4.2 x 8 mm screws. 1. For non-vented (recirculating) installations only, install charcoal filters over metal grease filter. See the “Range Hood Care” section. 2. Install metal filters. See the “Range Hood Care” section. 3. Check the operation of the range hood blower and light. See the “Range Hood Use” section. NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section.
RANGE HOOD CARE IMPORTANT: Clean the hood and grease filters frequently Non-Vented (recirculating) Installation Filters according to the following instructions. Replace grease filters before operating hood. The charcoal filter is not washable. It should last up to 6 months with normal use. Replace with Charcoal Filter Exterior Surfaces Kit Number W10412939. To avoid damage to the exterior surface, do not use steel wool or soap-filled scouring pads. To replace charcoal filter: 1.
WIRING DIAGRAM Push Button Switch Operation Function’) Position . Push Button Switch 6 L oN 6 G 6 6 3 9° e S| s| 1 2 No Connection Blue - Yellow Low Speed S| 8 =| a High Speed | Brown - Black § ac > POS 1 A 60 HZ 240 W Motor Resistance (Q) pee BU 28.8 30.3 aD Blue - Red Blue - White 37.7 45.
ASSISTANCE OR SERVICE If you need service geal a Please refer to the warranty page in this manual. if you need replacement parts If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance.
ATTACH YOUR RECEIPT HERE. PROOF OF PURCHASE WH I R L POO L® IS Please have the folowing information avattable when you call the MAJOR APPLIANCE a Name, address and telephone number LIMITED WARRANTY =A clear, detailed description ofthe problem " Proof of purchase including dealer or retailer narme and address | my Iw IF YOU NEED SERVICE: 1. Before contacting us to arrange service, please determine whether your product requires repair. Some questions can be addressed without service.