30" (76.2 CM) RANGE HOOD Installation Instructions and Use & Care Guide HOTTE DE 30" (76,2 CM) Instructions d’installation et Guide d’utilisation et d’entretien Table of Contents/Table des matières ..................................... 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY. IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS. POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY .................................................................3 INSTALLATION REQUIREMENTS.................................................5 Tools and Parts.............................................................................5 Location Requirements ................................................................5 Venting Requirements ..................................................................6 Electrical Requirements .................
RANGE HOOD SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS 4
INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Location Requirements IMPORTANT: Observe all governing codes and ordinances. here. It is the installer’s responsibility to comply with installation Tools needed model/serial rating plate is located inside the range hood on the left wall. Drill 11/4" (3.0 cm) drill bit 1/8" (3.
Cold Weather Installations Installation Clearances An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house.
3¼" x 10" (8.3 cm x 25.4 cm) Vent System Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. 6" (15.2 cm) or Larger Round Vent System Vent Piece Round 45° elbow 2.5 ft (0.8 m) 90° elbow 5.0 ft (1.5 m) 6" (15.2 cm) or larger wall cap 0.0 ft (0.0 m) 31/4" x 10" (8.3 cm x 25.4 cm) to 6" (15.2 cm) or larger Vent Piece 3¼" x 10" (8.3 cm x 25.4 cm) 90° elbow 5.0 ft (1.5 m) 3¼" x 10" (8.3 cm x 25.
Electrical Requirements Observe all governing codes and ordinances. Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
3. To wire through wall: Mark a line distance “A” from the right of the centerline on the underside of the wall. Mark the point on this line that is 3 ⁄4" (1.9 cm) from the underside of the cabinet. Drill a 11⁄4" (3.2 cm) diameter hole through the rear wall at this point. 3. Use saber or keyhole saw to cut a rectangular opening in the wall for the vent. Centerline Cabinet front ³⁄₈" (0.9 cm) 3 ⁷⁄₈" ³⁄₄" (1.9 cm) A Centerline (9.8 cm) 5¹⁄₄" (13.3 cm) 5¹⁄₄" (13.
2. Install Vent System 1. Install vent through the vent opening in upper cabinet or wall. Complete venting system according to the selected venting method. See “Venting Requirements” section. 2. Use caulking to seal exterior wall or roof opening around the cap. location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood. Set range hood aside on a covered surface. A Install Range Hood Complete Preparation 1. section. A.
7. E remove. Remove the terminal box cover and set it aside. A B C F D A A. Terminal box cover 8. Remove the power supply knockout from the top or rear of the vent hood (depending on the incoming location of your home power supply cable) and install a UL Listed or CSA approved ½" (1.3 cm) strain relief. A A. B. C. D. E. F. White wires Black wires UL listed wire connector Green (or bare) and yellow-green ground wire Home power supply cable UL listed or CSA approved ½" strain relief 2.
Liquid detergent or all-purpose cleaner: Rinse with clean water and dry with soft, lint-free cloth. RANGE HOOD USE The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen. The hood controls are located on the front panel on the right side of the range hood. A 1. C D A. B. C. D. Metal Grease Filter A A.
WIRING DIAGRAM YL/GN WH SEL0138395 MOTOR RESISTANCE (Ω) Red - Black 56.
ASSISTANCE OR SERVICE When calling for assistance or service, please know the purchase date and the complete model and serial number of your appliance. This information will help us to better respond to your request. If you need replacement parts If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance.
LIB0138872A/W11374529A /™ ©2019 Whirlpool. Used under license in Canada. All rights reserved. Utilisé sous licence au Canada. Tous droits réservés.