Use and Care Manual

9
3. Cut the duct to the measured size “X.”
4. Remove the air deector.
5. Slide the duct onto the bottom of the air deector.
6. Place the assembled air deector and duct over
theexhaustoutlet from the hood.
7. Reassemble the air deector to the duct cover bracket
withthe 2 assembly screws.
8. Seal connections with vent clamps.
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
aULlisted or CSA approved
1
/
2
" strain relief.
4. Run home power supply cable through strain relief
intoterminal box.
D
E
C
F
A
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-
green ground wires
5. Use UL listed wire connectors and connect
blackwires(C)together.
6. Use UL listed wire connectors and connect
whitewires(E)together.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
usingUL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
Install Vent Covers
NOTE: Remove protective lm from the vent covers.
1. When using both upper and lower vent covers, push lower
coverdown onto hood and lift upper cover to ceiling and
installwith (2) 2.9 x 6.5 mm screws.
A
C
E
C
D
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket
NOTE: For vented installations, the upper vent cover
maybereversed to hide slots.
Complete Installation
1. For non-vented (recirculating) installations only, install
charcoal lters over the blower motor. See the “Range Hood
Care” section.
2. Install metal lters. See the “Range Hood Care” section.
3. Check the operation of the range hood blower and light.
Seethe “Range Hood Use” section.
NOTE: To get the most efcient use from your new range
hood,read the “Range Hood Use” section.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
B