Installation guide

The console houses the electronic
control board, The board is factory
set for a dry time of 45 minutes,
Consult the tech sheet found inside
the dryer toe panel to reset dry time
and for other options,
The coin-slide mechanism, control
panel lock and key, and coin-box
lock and key are not included and
are available from usual industry
sources,
IMPORTANTSETUPINFORMATION
The electronic control isfactory
preset to accept commands from a
Palm®handhold equipped with the
appropriate Whirlpool management
software, If a handheld is not to be
used, the handhold functionality
MUST BEDISABLED as part of the
control set up, Failure to disable
handhold functionality may result in
unauthorized machine access,
Exhaust
requirements
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to do so can result in
death or fire,
Do not use non-metal flexible vent,
metal vent that issmaller than four
inches in diameter or exhaust hoods
with magnetic latches,
The dryer must be exhausted outdoors.
Do not exhaust dryer into a gas vent,
chimney, wall, ceiling, or concealed
space of a building,
Do not install flexible vent in enclosed
walls, ceilings or floors,
If using an existing exhaust system,
clean lint from entire length of exhaust
system, Make sure exhaust hood is not
plugged with lint,
The exhaust system should be
inspected and cleaned yearly,
Replace any plastic or metal foil
exhaust vent with rigid metal or flexible
metal vent,
Use 4" (10,2 cm) vent clamps to
secure vent system,
exhaust airflow
beffer [==]good P]
Four-inch (10.2 cm) metal exhaust vent
isrequired, Plan installation to use the
fewest number of elbows and turns,
Metal flexible vent must be fully
extended and supported when the
dryer is in its final position, DO NOT
KINK OR CRUSH THE VENT, The metal
flexible vent must be completely
open to allow adequate exhaust air
to flow.
Allow as much room as possible
when using elbows or making turns,
Bend vent gradually to avoid kinking,
Remove excess flexible vent to avoid
sagging and kinking that may result in
reduced air flow,
Exhaust outlet is located at the
center of the bottom dryer back,
The exhaust vent can be routed up,
down, left, right, behind the dryer or
straight out the back of the dryer,
Maximum length of exhaust system
depends upon the type of vent used,
number of elbows and type of
exhaust hood, The maximum length
for both rigid and flexible vent is
shown in the chart,
EXHAUSTHOOD TYPE
r 4•
(10.2 cm) 10.2 cm)
turns _ y
MAI_MUMLE_I_lltOF 4-1N_'tRIGIDMETALt_NT10.2 _ DIAMEI_R
8 64FT.119.5ml 64 FT.(19.5ml 58FT.117.7r_
1 54 FT.(16.5 m) 54 FT.116.5 m) 48 FT.(14_ n0
2 44 FT.(13.4 rn] 44 FT.(13.4 rn] 38 FT.(11_ n0
3 36 FT.(10.7 m) 36 FT.(I0.7 m) 29 FT.(8.8 m]
4 27 FT.(8.2 m) 27 FT.(8.2 m) 21 FT.(5.4 m)
MAXIMUMLEN@111OF4-1NCH(I 0.2cm) DIAMb'IIER
FL_BLEMETALVENT
O 36 FT.(11.0 m) 36 FT.(11.0 m) 28 FT.(8_ m)
I 31 FT.(gA m) 31 FT.(9.4 m) 23 FT.(7_ m)
2 27 FT.(8.2 n0 27 FT.(8.2 m) 19 FT.(6Ji m]
3 25 FT.(7_ rn) 26 FT.(7.6 m] 17 FT.(6.2 m]
4 23 FT.(7.On0 23 FT.(7.0 m] 15 FT.(4_ m]
For exhaust systems not covered by
the exhaust length chart, see
Whirlpool Service Manual, "Exhausting
Whirlpool Dryers," Part No, 603197,
available from your Whirlpool parts
distributor,
If dryer is installed in a confined area,
such as a bedroom, bathroom or
closet, it must be exhausted to the
outside and provision made for
enough air for combustion and
ventilation, (Check governing codes
and ordinances,) See "Recessed area
and closet installation instructions" on
Page 12,
Page 3