Installation guide

27-1/2"
(69.9cm)
recessed
height
23"
(58.4 _4_
cm)
max.
recessed
depth
Single oven
25-3/8"
(64.5 cm) max.
(68 cm)
overall width
29"
(73.7 cm}
max.
overall
height
49-1/2"
1125.7cm)
recessed
height
Double oven
25-3/8"
(64.5 cm) max.
23" 26-3/4"
cm)
(58.4 cm) \ overall width
max.
recessed
depth
j-
51"
1129.5cm)
max,
overall
J
27" (68.6 cm) ram. _1
cabinet width
q
25-1/2"
(64.8 cm}
cuteut width
Single oven
undercounter
(without cooktop
installed above)
1-1,
(3.8 cm) min. A
top of cutout
T
to underside
of countertop
49-3/4"
1126.4 cm)
min,
cutout
height
5-1/4" 113.3cm}
bottom of cutout
to floor _-
1-1/2" 13.8cm)
rain. bottom of
cutout to top of
cabinet door
27" (68.6 cm) ___,,
4-- min. cabinet
l
25-1/2"
(64.8 cm)
___ cutout
width
1" (2.5 cm) top
of cutout to
bottom of upper
cabinet door
14-3/4"
(37.5 cm)
bottom of
cutout to floor
Double oven
27-3/4"
(70.5 cm)
min.
cutout
height
1-1/2"
(3.8 cm)
min.
bottom of
cutoutto
top of
cabinet
door
27"(68.6 cm)
min.
cabinet width
25-1/2"
_(64.8 cm)_
cutout
width
1" (2.5 cm) top
of cutout to
bottom of upper
cabinet door
32"
181.3cm)
bottom of
cutout to
floor
Single oven
cabinet---_
23-1/4"
159.1cm) min.
cutout depth
23" (58.4 cm)
"_-_recessed oven_
depth
J
recessed
oven
Cabinet side view
_even
front
Important: Observe all governing codes
and ordinances.
Proper installation is your responsibility.
Have a qualified technician installthis oven.
Oven location should be away from strong
draft areas, such as windows, doors and
strong heating vents.
Cabinet opening dimensions that are shown
must be used. Given dimensions provide
minimum clearance.
Recessed installation area must provide
complete enclosure around the recessed
portion of the oven.
Electrical ground is required. See "Electrical
requirements."
Electrical supply junction box should be
located 3 inches(7.6 cm) maximum belowthe
support surface when oven isinstalled in a
wall cabinet. Drill a 1-inch minimum (2.5 cm)
diameter hole inthe right rear or left rear
corner of the support surface to pass the
appliance cable through to the junction box.
For undercounter installation, it is
recommended that the junction box be
located inthe adjacent right or left cabinet. If
installingthe junction box on rear wall behind
oven, junction box must be recessed and
located inthe upper or lower right or left
corner of cabinet.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is
adequate and in conformancewith National
Electrical Code, ANSI/NFPA 70 m latest
edition*, or Canadian Electrical Code, 022.1-
1982 and 022.2 No. 01982 (or latest edition)**
and all local codes and ordinances.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
** Canadian Standard Association
178 Rexdale Boulevard
Etobicoke, Ontario, Canada Mgw 1R3
Tool needed:
S
screwdriver
Partssupplied:
4 screws (double oven)
C' apns
Note: If installinga single oven, you will need
only two screws and two door removal pins.
Page 1