Installation guide

@
Aseparate
30
amp
circuit
for
electric
dryers.
@
Aseparate
15
or
20
amp
circuit
for
gas
dryers.
@
if
you
are
using
power
supply
cord,
a
grounded
electrical
outlet
located
within
2
ft.
(610
mm)
of
either
side
of
dryer.
See
“Electrical
Requirements.”
@
A
sturdy
floor
to
support
dryer
and
a
total
weight
(dryer
and
load)
of
200
Ibs.
(90.7
kg).
The
combined
weight
of
a
companion
appliance
should
also
be
considered.
@
Level
floor
with
maximum
slope
of
1"
(25
mm)
under
entire
dryer.
If
slope
is
greater
than
1"
(25
mm),
install
Extended
Dryer
Feet
Kit,
Part
Number
279810.
If
not
level,
clothes
may
not
tumble
properly
and
automatic
sensor
cycles
may
not
operate
correctly.
Do
not
operate
your
dryer
at
temperatures
below
45°F
(7°C).
At
lower
temperatures,
the
dryer
might
not
shut
off
at
the
end
of
an
automatic
cycle.
Drying
times
can
be
extended.
The
dryer
must
not
be
installed
or
stored
in
an
area
where
it
will
be
exposed
to
water
and/or
weather.
Check
code
requirements.
Some
codes
limit,
or
do
not
permit,
installation
of
the
dryer
in
garages,
closets,
mobile
homes,
or
sleeping
quarters.
Contact
your
local
building
inspector.
NOTE:
No
other
fuel-burning
appliance
can
be
installed
in
the
same
closet
as
a
dryer.
Installation
clearances:
The
location
must
be
large
enough
to
allow
the
dryer
door
to
open
fully.
Most
installations
require
a
minimum
5%"
(140
mm)
clearance
behind
the
dryer
for
the
exhaust
vent
with
elbow.
See
“Venting
Requirements.”
29"
Wide
Models
Dryer
Dimensions
197/,"
(349
mm)
#97),
*
A
-
QP,
x
(705
mm)
(705
mim)
A.
Wide
opening
side-swing
door
B.
Wide
opening
hamper
door
installation
Spacing
+
gis
beta"
max’
(76
mm}
ee
Tk
18"
aie
|
ies
mo
Ee
f
(457
mm)
WILL
CN)
q
=
fr
8
|
CHR
ain’
FE
aly
om
(15cm)
(76
mm)
>|
be
20"
>
a
lt
ore
mB
(5mm)
(737mm)
(25
mm)
(25mm)
(705mm)
(140
mm)
A B
Cc
A.
Recessed
area
B.
Side
view
closet
or
confined
area
C.
Closet
door
with
vents
“Required
spacing
27"
Wide
Models
Dryer
Dimensions
43"
(1082
mm)
oe
(
mm).
1354"
{349
mm)
*291/,"%
(749
mm),
\
On
\
Oy
a
—Ne686
mm)
686
mm)
A B
A.
Large
opening
side-swing
door
B.
Wide
opening
hamper
door
installation
Spacing
4
gis
(mm)
OF
ee
eee
aa
Wena
he
r
(656
mm)
“Bin”
(10cm)
2.
18°"
OFO
i
(457
mt
:
_ f
La
8
alt
gue
(76
mm)
CBN
J
|
sin”
bh
pe
u
O
(1850mi
>|
27"
>|
1
>
H
200>
Lae
25mm}
(686
mm)
(25
mm)
25
mm)(749
mm)
(440
mm)
A B
Cc
A.
Recessed
area
B.
Side view
closet
or
confined
area
C.
Closet
door
with
vents
“Required spacing
installation
spacing
for
recessed
area
or
closet
The
dimensions
shown
are
for
the
minimum
spacing
allowed.
@
Additional
spacing
should
be
considered
for
ease
of
installation
and
servicing.
@
Additional
clearances
might
be
required
for
wall,
door,
and
floor
moldings.
@
Additional
spacing
of 1"
(25
mm)
on
all
sides
of
the
dryer
is
recommended
to
reduce
noise
transfer.
@
For
closet
installation,
with
a
door,
minimum
ventilation
openings
in
the
top
and
bottom
of
the
door
are
required.
Louvered
doors
with
equivalent
ventilation
openings
are
acceptable.
@
Companion
appliance
spacing
should
also
be
considered.
Mobile
home
Additional
installation
requirements
This
dryer
is
suitable
for
mobile
home
installations.
The
installation
must
conform
to
the
Manufactured
Home
Construction
and
Safety
Standard,
Title
24
CFR,
Part
3280
(formerly
the
Federal
Standard
for
Mobile
Home
Construction
and
Safety,
Title
24,
HUD
Part
280)
or
the
Canadian
Manufactured
Home
Standard
CAN/CSA-Z240
MH.
@
Metal
exhaust
system
hardware,
available
for
purchase.
For
further
information,
please
reference
the
“Assistance
or
Service”
section
of
the
“Use
and
Care
Guide.”
@
Special
provisions
must
be
made
in
mobile
homes
to
introduce
outside
air
into
the
dryer.
The
opening
(such
as
a
nearby
window)
should
be
at
least
twice
as
large
as
the
dryer
exhaust
opening.