Installation and Operation Guide
PART 2: FAN MOTOR INSTALLTION GUIDE
Inline Solution
Models included: IL-800 and IP-1140
17
Positioning your KLEENAIR Unit:
It is recommended that the KLEENAIR INLINE unit be mounted 
in a roof space or wall cavity. Please ensure that the KLEENAIR 
unit is positioned in an environment that is free of other gases 
to enable an efcient expulsion of the cooking by-products 
and to ensure that back draft of external gases doesn’t take 
place. 
Please ensure the fan motor is positioned away from other 
exhausts such as chimneys, gas ues, etc. The inline unit can 
be mounted so that it ducts directly through the wall or eave 
vent.
STEP 1:
Establish a suitable position in the roof or wall cavity for the 
KLEENAIR unit, ensuring that the distance between the 
KLEENAIR unit and the outside vent is no greater than 
800mm. The KLEENAIR unit must be located a minimum 
of 3 metres from the hood unit.
STEP 2:
Using the mounting bracket and screws, mount the KLEENAIR unit to a beam, truss or another appropriate structures in the roof 
or wall space through the rubber grommets. Hang the fan motor unit from the mounting bracket ensuring the mounting bracket 
is located at the top of the unit. Ensure the direction of airow is toward the outside. The direction of airow is marked on the 
KLEENAIR unit.
STEP 3:
Cut a 200mm diameter hole in the wall or eave to enable the mounting of the external vent. Please ensure that the hole is cut in 
a practical position to enable the exi-duct to be secured. Attach the exi-duct to the vent and then mount vent to the wall or 
eave.
STEP 4:
Attach the exi-duct from the external vent to the outlet of the KLEENAIR unit using pipe clamps. To minimise inefciencies and 
noise ensure the duct is pulled tight and the 200mm diameter is maintained.
STEP 5:
Attach exi-duct from the KLEENAIR unit to the rangehood using pipe clamps. Ensure that the duct is pulled tightly to ensure that 
exi-duct remains rm and stable during operation. Avoid sharp bends in the duct. 
Gentle bends in the ducting are 
recommended as it assists in mufing noise from the fan motor unit back to the rangehood
. If the exi-duct needs to be 
extended attach two exi-duct ends using a rigid duct insert and secured by pipe clamps (Optional installation accessories 
HBX200DUCT).
STEP 6:
Attach the male plug of the KLEENAIR unit to the female plug of the rangehood to enable power supply to the fan motor unit. An 
extension lead (not supplied) of up to ve meters may be added if required.
OutletMounting Bracket
Inlet