Technical information
TROUBLE SHOOTING   
32  May 2010 / M-SC3.5 / EN 
PROBLEM  POSSIBLE CAUSE  WHAT TO DO? 
• Low oil level.  Fill up with oil. 
• Water inlet system blocked. 
• Broken impeller.  
• Water strainer choked. 
• Heat exchanger choked. 
Check the cooling system thoroughly. 
  • Faulty thermostat  Check the thermostat or replace. 
Engine stops very slowly  • Engine should stop within 20 seconds.  Stop solenoid is faulty and engine is stopped 
by after pushing stopping button fuel shut off 
valve. 
5.2.4 Warnings 
Generator must be shut off immediately if: 
● Motor RPM suddenly rises or drops; 
● Unusual noise comes from generating set; 
● Exhaust gases suddenly colour dark; 
● Display of the MasterView Easy shows a warning. 
5.2.5 Service address 
If you cannot correct a problem with the aid of the mal-
function table, contact your Whisper Power Service Centre 
or Whisper Power Netherlands, tel: INT+31-512-571550. 
www.whisperpower.eu. 