Platinum Split OWNER’S MANUAL The Coolest Thing In Wine Storage PS 102113
We manufacture, test and certify 100% of our wine cooling units in the USA. By sourcing the best components and closely controlling our manufacturing processes, we can assure the highest-quality, lowest defect manufacturing rates in the industry. Copyright © 2012. WhisperKOOL. All rights reserved. This manual, the product design, and the design concepts are copyrighted by WhisperKOOL, with all rights reserved.
TABLE OF CONTENTS Quick Reference Guide Evaporator Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Controller Layout & Specifications. . . . . . . . . . . . . . . . . . . . . . . . 3 Fully Ducted Unit & Specifications. . . . . . . . . . . . . . . . . . . . . . . . 4 Receiving & Inspecting The System. . . . . . . . . . . . . . . . . . . . . . . . . 5 Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
QUICK REFERENCE GUIDE Platinum Split Evaporator Unit (Fan Coil Unit) Front / Side View Evaporator Unit (Fan Coil Unit) °F Filter Grille Controller Platinum Split Evaporator Unit (Fan Coil Unit) Rear / Side View Mounting Key Hole (X4) THROUGH THE WALL Option 1 Knock Out For Wiring Knock Out For Suction Line Knock Out For Liquid Line Knock Out For Drain Line Circular Connection Mounting Location INSIDE CELLAR Option 2 Liquid Line Knock Out Suction Line Knock Out Page 2 | 1-800-343-9463 Knock Out For Dra
QUICK REFERENCE GUIDE Controller Layout °F °F Refer to page 11 for complete listing of buttons and symbols. High History Scroll Button °F Inactive Cellar Pre-Chill (Press and hold 3-5 sec) °F °F °F Low History Scroll Button View Set Point Change Set Point (Press and hold 3-5 sec) Power On/Off Compressor On Unit is in Pre-Chill Mode Fans are On Alarm is Present Unit is in Anti-Frost Mode Wall Mounted PLATINUM SPLIT UNIT SPECIFICATIONS Model Cellar Size (cu. ft.) Dimensions 20.5”w x 15.
QUICK REFERENCE GUIDE Platinum Split Evaporator Unit (Fan Coil Unit) Front / Side View Supply Air Return Air °F Keypad Duct Plenum DUCTED PLATINUM SPLIT UNIT SPECIFICATIONS 4000 Condenser (Air Cooled Condensing Unit) 4000 Evaporator (Fan Coil Unit) Model Cellar Size (cu. ft.) 1000 Dimensions 23.75”w x 15”h x 22.5”d BTUh with 90° air entering the Condenser Coil 2000 12”w x 13.5”h x 18”d 23.75”w x 15”h x 22.
RECEIVING & INSPECTING THE SYSTEM Receiving and Inspecting the System • Lift only at the designated hand hold locations on the shipping container or fully support the unit from • • • underneath. A shipment may include one or more boxes containing accessories. Before opening the container, inspect the packaging for any obvious signs of damage or mishandling. Write any discrepancy or visual damage on the Bill of Lading before signing. Allow the condensing unit to sit for 24 hours prior to start up.
BEFORE YOU START 1. Inspect all components prior to installation. If damage is found, please contact your distributor or WhisperKOOL Customer Service at 1.800.343.9463. 2. The Condensing Unit requires a dedicated 115-volt 20-amp circuit. Use a surge protector with the unit. Do not use a GFI (Ground Fault Interrupter) line. 3. It is REQUIRED to install a drain line to remove condensation from the Evaporator Unit (Fan Coil Unit). 4.
PREPARING THE WINE CELLAR The performance and life of your system is contingent upon the steps you take in preparing the wine cellar. Note: Improperly preparing your enclosure or incorrectly installing your unit may cause unit failure, leaking of condensation, and other negative side effects. IT IS HIGHLY RECOMMENDED THAT YOU OBTAIN THE ASSISTANCE OF A WINE STORAGE PROFESSIONAL.
Unobstructed Airflow Unobstructed airflow to and from the system is critical for the system’s overall performance and life-span. A minimum three-foot clearance (five foot is ideal) area is crucial. The air the fans blow needs to circulate and either dissipate or absorb heat from the space, the more air to exchange the more efficient the system will operate. Note: Avoid attempting to camouflage the unit. This will restrict airflow and thus the systems’s ability to work efficiently.
Ventilation The necessity of dissipating heat away from the condensing unit is critical to the performance and cannot be overstated. As the system operates and cools, a greater amount of heat is generated on the condensing side of the system. Adequate ventilation is required in order to dissipate heat away from the condensing unit. If ventilation is inadequate, the exhaust will heat up the area or room and adversely affect the systems ability to cool.
SYSTEM OPERATION Initial Start-Up When power is applied to the unit, the control will briefly display all symbols, and the Snow Flake symbol will be displayed (if unit is calling for cooling). There may be a brief delay prior to the evaporator fan turning on, as the fan will not turn on until the evaporator probe temperature drops below 70°F. When the evaporator fan is activated the Fan symbol will be displayed. The temperature control feature for the evaporator fan is a feature applicable to WhisperKOOL.
CONTROLLER FUNCTIONS If your unit has a remote keypad then you will have the Remote Controller. High Temp / Pre-Chill Low Temp Display Set Point ON / OFF TEMPERATURE Button Normal Functions ON/OFF • The ON/OFF button allows the customer the convenience of turning the refrigeration system ON or OFF, from the control panel. This feature does not disconnect power from the unit. In order for the power to be shut off from the unit, the power cord must be unplugged from the wall receptacle.
Set 1. Press the “Set” button once and it will display the Set Point. After approximately 5 seconds, the display will return to normal operation and display the Bottle probe temperature. 2. Press the “Set” button once and it will display the Set Point. Press the up and down arrows to change the set point. Press the Set button again and the numbers will blink, confirming the change in Set Point. 3.
CPSM Mode Press the “Set” and the “Down Arrow” buttons simultaneously, for 3-5 seconds, and you will access the “Customer Preference Selection Mode” (CPSM). The CPSM allows the customer to “Fine Tune” the Control Operating System to their applicable choice. The following CPSM options are available for adjustment: Fon – Humidity Management Enhancement: This parameter is normally set at 0, which should provide adequate relative humidity for the cellar.
MAINTENANCE SCHEDULE Monthly 1. Check coils 2. Check for unusual noise or vibration 3. Check the drain line to see if it is above the waterline if draining into a vessel. Quarterly 1. Use a vacuum with brush attachment to clean coils. Be careful not to crush coil fins when cleaning. Annually 1. Inspect for corrosion. 2. Check wiring connections and integrity of cords. 3. Pour a 50/50 bleach solution into the drain line every spring.
TROUBLESHOOTING GUIDE Unit has ice forming on the Evaporator Unit (Fan Coil Unit) Possible Cause Solution Evaporator filter or coil is dirty. Remove the filter and wash, then clean the coil with a vacuum. If coil is very dirty, use a spray bottle with a small amount of liquid dish washing detergent or coil cleaner. Spray coil, let set for 5 min, then flush with fresh water. There is something blocking the supply and or return air Remove blockage The evaporator fan is not turning on.
TROUBLESHOOTING GUIDE Unit leaks water Possible Cause Solution Evaporator Unit (Fan Coil Unit) is not level Evaporator Unit (Fan Coil Unit) should be level on the wall to prevent leaking. Drain line clogged or kinked Check drain line to make sure water can flow freely.
TECHNICAL ASSISTANCE WhisperKOOL Customer Service is available Monday through Friday from 8:00 a.m. to 4:00 p.m. Pacific Time. The customer service representative will be able to assist you with your questions and warranty information more effectively if you provide them with the following: • The model and serial number of your WhisperKOOL systems. • Location of unit and installation details, such as ventilation, ducting, construction of your wine cellar, and room size.
The Coolest Thing In Wine Storage Split System Series Product Warranty Information WhisperKOOL Product Terms and Conditions Including Product Limited Warranty And Product Installation Requirements For WhisperKOOL Split System Series ATTENTION: PLEASE READ THESE TERMS OF USE CAREFULLY BEFORE INSTALLING YOUR WHISPERKOOL COOLING SYSTEM. INSTALLING YOUR WHISPERKOOL COOLING SYSTEM INDICATES THAT YOU ACCEPT AND AGREE TO EACH OF THE TERMS AND CONDITIONS SET FORTH HEREIN (“TERMS OF USE”).
The following part or cause of failure is not the responsibility of WhisperKOOL: • Improper voltage supply • Line set with screw connectors (high end and low end) • Leaks found at the braze points when performing pressure check • Unit that has been charged incorrectly • Incorrect tubing diameter used on line set • A unit that has been wired incorrectly • Valve stem on condenser side • Improper installation of P-Trap • Lack of P-Trap (if required) • Condensers that are installed outdoors or in elements that
1. AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXPRESSLY DISCLAIMED. Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This limited warranty gives you specific legal rights, and you may have other rights, which vary from state to state. 2.
5. Sales and Use Tax WhisperKOOL only collects California sales tax for orders shipped within the State of California; WhisperKOOL does not collect sales tax for orders shipped to other states. However, the Purchaser and the End User may be liable to the taxing authority in their state for sales tax and/or use tax on the Product. The Purchaser and the End User should each check with their state’s taxing authority for sales and use tax regulations. 6.
change or update these Terms and Conditions, at any time without prior notice. 9. Questions, Additional Information And Technical Assistance A. Questions. If you have any questions regarding these Terms and Conditions or wish to obtain additional information, contact us via phone at 1-800-343-9463 or please send a letter via U.S. Mail to: Customer Service WhisperKOOL Corporation 1738 E Alpine Ave Stockton, CA 95205 Email: support@whisperkool.com Web: www.whisperkool.com B. Technical Assistance.
WhisperKOOL 1738 E. Alpine Ave Stockton, CA 95205 1(800) 343-9463 www.whisperkool.