Troubleshooting guide

Page 12 PT-EXPL01 071609
Sheetrock alone cannot support the weight of a
65-pound (or more) cooling system. Therefore, it
is necessary to frame the hole that you have just
cut with upper and lower supports.
Using two 2x4s at 14.5” in length and eight 6d
nails, secure the upper and lower supports to
the right and left studs, just inside the sheetrock.
Make sure that the internal height remains at 16”
so that the WhisperKOOL system will  t snugly
through the framed cut-out.
Frame the hole with two-by-four supports
Once the horizontal lines have been cut, make vertical cuts using the inside edge of the studs as a guide.
Once you have made both vertical cuts, you should have a rectangular hole in the sheetrock. Now you have
to make the same hole on the other side of the wall. Since you already have one hole, this is an easy process.
Using a nail, mark all four corners of the  rst hole by making nail holes through the sheetrock. Then on the
other side of the wall, connect the holes with a pencil mark and cut.