250/1750/2750 Manual 3/6/02 2:45 PM Page 1 OWNER’S MANUAL 1000/2000 WATT SERIES THE WHISTLER GROUP CORPORATE HEADQUARTERS 13016 N. Walton Blvd. Bentonville, AR 72712 TEL (479) 273-6012 FX (479) 273-2927 www.whistlergroup.com HIGH SURGE POWER INVERTERS PRODUCT DEVELOPMENT CENTER 25 Industrial Ave. Chelmsford, MA 01824 TEL (978) 244-1400 FX (978) 244-1491 CUSTOMER RETURN CENTER 1201 N. Dixieland Rd. Rogers, AR 72756 Consumer Relations Tel (800) 531-0004 Email: info@whistlergroup.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 3 INTRODUCTION If you have questions concerning the operation of this Whistler product please call consumer relations: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT Please keep the receipt in a safe place. If the unit is returned without a dated proof of purchase, an out of warranty service charge applies. Note: Your warranty period begins at the time of purchase. The warranty is validated only by your receipt.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 5 TABLE OF CONTENTS Topic WHISTLER FEATURES Page Features Summary ..................................................................3-7 Important Information................................................................8 Inverter Information............................................................9 • Getting Started • Don’t Push It Battery Information...........................................................
1250/1750/2750 Manual 3/6/02 2:45 PM Page 7 FEATURES FEATURES for safe operation. When this occurs, turn the equipment or appliance off. In the event of excess temperature, the High Speed Cooling Fan also will automatically turn on. Overheating may result when the inverter is being operated at levels exceeding its wattage rating or because it has been placed in a location or in an manner which prevents proper heat dissipation.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 9 FEATURES e). Two Standard North American 110 AC Outlets are provided. f).Remote Operation Socket. The inverter is designed to be operated from a remote location via the WHISTLER PP015DC Remote Control Switch which plugs into this socket. This optional accessory is available through WHISTLER or your WHISTLER dealer. FEATURES Note: The 2000 series inverters incorporates all of the operating and safety features of the 1000 series models.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 11 IMPORTANT INFORMATION Important Information About Your New Whistler Inverter. This manual will provide you with directions for the safe and efficient operation of your Whistle Power Inverter. Important Note: Each of the following operating procedures and safety features must be carefully reviewed and thoroughly understood prior to using the inverter. Failure to do so may result in damage to the inverter or equipment or serious personal injury.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 13 INVERTER INFORMATION Don’t Push It. Although your Whistler power inverter has the capacity to provide power output (excess current) equal to approximately two times its rated wattage capacity for a very brief period, it is designed to operate equipment and appliances with start up load wattage ratings no higher than its own maximum continuous wattage rating. For example, the 1500 model has a maximum continuous rating of 1500 watts.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 15 BATTERY/CABLE INFORMATION BATTERY INFORMATION 1. 2. To calculate the amp/hour of the battery, first determine its "reserve minutes" rating. (Deep cycle marine batteries generally have the highest reserve minute ratings). This rating typically is marked on the battery along with the "Cold Cranking Amps" (CCA) rating. Multiply the reserve minutes rating of the battery by 0.3 to determine the battery amp/hour rating of 50 (166 x 0.3 = 49.8).
1250/1750/2750 Manual 3/6/02 2:45 PM Page 17 OPERATION CABLE INFORMATION Regardless of the wire gauge selected to make the connections to the battery, we recommend use of an "O Ring Adapter." Use of #0 gauge wire to make the connections to the inverter may require a "0 to 4 Gauge Adapter." Both adapters are available through electronic supply stores including Radio Shack. Radio Shack part number is listed below: O Ring Adapter: Making the Connection. 1. 2.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 19 OPERATION OPERATION Note: • Loose connections can result in a severe decrease in voltage which may cause damage to the wires and insulation. • Failure to make proper connection between the inverter and the power source will result in reverse polarity. Reverse polarity will blow the internal fuses in the inverter and may cause per -manent damage to the inverter. Damage caused by reverse polarity is not covered under the Whistler warranty.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 21 OPERATION • appliance or equipment being operated will not significantly decrease the power being generated by the inverter. For best operating results, the extension cord should be no more than 50 feet long. • Check frequently to ensure that the input and out put connections are secure. Loose connections may damage the inverter, the power source, or may generate excessive heat. The following precautions apply to the 2000 series models only. OPERATION b).
50/1750/2750 Manual 3/6/02 2:45 PM Page 23 OPERATION OPERATION If you are using the inverter while the engine is off, we recommend you start the engine every 30 to 60 minutes and let it run for at least 10 minutes to recharge the battery. We also recommend that the device plugged into the inverter be turned off before turning over the engine. 3. Isolate the television, its power cord and antenna cables from the 12 volt power source by running an extension cord from the inverter to the television set.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 25 OPERATION Some Powerful Advice. OPERATING PRINCIPALS • VENTILATION. In order to disperse the heat generated while the inverter is in operation, keep it well ventilated. While in use, maintain several inches of clearance around the top and sides of the inverter. • FUMES & GASES. Avoid using the inverter near flammable materials. Do not place the inverter in areas such as battery compartments, where fumes or gases may accumulate.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 27 OPERATING PRINCIPALS OPERATING PRINCIPALS/SUMMARY This stepped waveform is similar to the power generated by utilities and has a broad range of applications. For more information on inverters see our Inverter FAQ page at www.whistlergroup.com/faq-inverters.asp The modified sine wave produced by your Whistler Inverter The modified sine wave produced by your Whistler inverter has a root mean square (RMS) voltage of 110 volts.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 29 OPERATION SUMMARY • If the rated power consumption of the equipment is in the range of the maximum specified wattage of your converter, test the inverter to ensure that it will operate properly. OPERATION SUMMARY • When in use, make certain that the inverter is properly ventilated. • Do not use the inverter near flammable materials, fumes, or gases. • Always operate the inverter in accordance with the instructions in this manual.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 31 TROUBLESHOOTING TROUBLESHOOTING Overload or High Temp LED on PROBLEM: TV Interference Problem Solution Electrical interference from inverter. Add a Ferrite data line filter on to the TV power cord. This filter is available at RadioShack, part number 273-105. PROBLEM: Low or No Output Voltage Problem Solution Using incorrect type of Use true RMS reading voltmeter to test output meter. voltage. See "For You Technical Types" Section of this manual.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 33 SPECIFICATION WARRANTY WHISTLER PP1000AC & PP1250AC WATT INVERTER SPECIFICATIONS Maximum Continuous Power………………1000 Watts/1250 Watts Maximum Surge Capability (Peak Power)...2000 Watts/2500 Watts No Load Current Draw……………………………….............<0.32 A Waveform……………………………….............Modified Sine Wave Operating Input Voltage Range…………….............10-15 Volts DC AC Receptacle……………………..............Dual 3 Prong Grounded Approximate Dimensions................ 3.
1250/1750/2750 Manual 3/6/02 2:45 PM Page 35 WARRANTY IMPORTANT: Whistler will not assume responsibility for loss or damage incurred in shipping. Therefore, please ship your inverter insured with return receipt requested. 2. Include with your unit the following information, clearly printed: • Your name and street address (for shipping via UPS), a daytime telephone number, (No P.O. Box please.) and email address (if applicable). • A detailed description of the problem, i.e. Unit powers up but no AC output.