INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL The Tahoe Direct Vent Zero Clearance Gas Fireplace Heater LUXURY DIRECT VENT GAS FIREPLACE HEATER MODEL SERIES MILLIVOLT STANDING PILOT DVX36FP32CL(N,P)-1 DVX36FP33CL(N,P)-1 DVX42FP32CL(N,P)-1 DVX42FP33CL(N,P)-1 REMOTE RF MODELS DVX36FP93CL(N,P)-1 DVX42FP93CL(N,P)-1 GAS-FIRED Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. UL FILE NO.
TABLE OF CONTENTS Section Page Important Safety Information...................................................................................................................... 3 Safety Information for Users of LP Gas ..................................................................................................... 4 Requirements for Massachusetts ................................................................................................................. 5 Introduction ...........................
IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED • If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. The base referred to above does not mean the fireproof base as used on wood stoves.
SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now, then review them point by point with the members of your household. Someday when there may not be a minute to lose, everyone’s safety will depend on knowing exactly what to do.
REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 1. INSTALLATION OF CARBON MONOXIDE DETECTORS.
INTRODUCTION Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with the fireplace. 3. Installer should show owner how to start and operate the fireplace. This direct vent gas fireplace heater is designed to operate with all combustion air being siphoned from the outside of the building and all exhaust gases expelled to the outside of the building.
SPECIFICATIONS DVX36 NAT DVX36 LP DVX42 NAT DVX42 LP Input Btu/hr Maximum 35,000 30,000 37,500 35,000 Btu/hr Minimum 24,000 21,000 26,000 24,000 10.3 8.8 11.0 10.3 KWH (Maximum) (Minimum) Orifice Air Shutter Opening 7.2 6.2 7.6 7.2 #32 (P-211) 1.65mm (P-250) #31 (P-209) #50 (P-245) 1/4"(6.4mm) FULL OPEN 1/4" (6.4mm) FULL OPEN 34 3/4 (3.2mm) 34 3/4" (3.2mm) 34 3/4" (3.2mm) 34 3/4" (3.
CLEARANCES Mantel Chart (Figure 3) Clearance to Combustibles Back 0" (0 mm) Side 0" (0 mm) Floor 0" (0 mm) 0" (0 mm) Top Stand-off Top Framing Edge 6" (152 mm) 12” (305mm) 10” (254mm) MANTEL COMBUSTIBLE TRIM AND MANTELS ALLOWED IN SHADED AREA 8” 6” 19” 4 1/2” 3 3/4” 3” 18 3/4” 2 1/4” 1 1/2” 17” 16” 15” 3/4” 14” 13” 12” 11” 10” TOP EDGE OF FIREPLACE Figure 3 Clearances (Figure 4) Clearance from top front edge of fireplace to ceiling is 36" Clearance from side of fireplace to adjacent sidewall is
GAS SUPPLY The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter Tubing, Type L Outside Diameter Nat. L.P. Nat. 0-10ft 0-3m 1/2" 12.7mm 3/8" 9.5mm 1/2" 3/8" 12.7mm 9.5mm 11-40ft 4-12m 1/2" 12.7mm 1/2" 12.7mm 5/8" 1/2" 15.9mm 12.7mm 41-100ft 13-30m 1/2" 12.7mm 1/2" 12.
INSTALLATION Framing and Finishing 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame. 3. Attach fireplace to frame using adjustable frame. Preset depth to suit facing material (adjustable to 1/2", 5/8" or 3/4" depths). 4. Use (8) 1/2" hex-head screws supplied in hardware package, to screw through slotted holes in drywall strip and then screw into pre-drilled holes on fireplace side.
INSTALLATION (continued) Flush Mount Mantel Installation (Figure 10) The fireplace must extend 3/4" beyond finished wall surface when using a flush mount mantel. Refer to Figure 10 to locate nailing flanges on fireplace sides. Mark and drill two (2) 1/8" holes into fireplace side to mount each nailing flange. Use eight (8) 1/2" hex-head screws supplied in hardware package to attach nailing flanges to fireplace sides.
Flush Wall Installation Attention: Cold climate installation recommendation: When installing this unit against a non-insulated exterior wall, it is recommended that the outer walls be insulated to conform to applicable insulation codes. Vent Runs (Figures 14, 15, and 16) In planning the installation for the fireplace, it is necessary to install certain components before the appliance is completely positioned and installed.
INSTALLATION (continued) VERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALL CORNER INSTALLATION VERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALL “A” PIPE LENGTH 90º ELBOW WALL FIRESTOP/ THIMBLE “A” “B” 6” (152mm) MINIMUM “C” VENT CAP 9” (229mm) MINIMUM “D” VENT CAP WALL FIRESTOP/ THIMBLE Dim.
VENTING FIREPLACE - TOP To Use the Vent Graph (Figure 17) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the bottom of the graph. 3. Select the indicated dimension, and position the unit in accordance with same.
VENTING FIREPLACE - TOP (continued) Below Grade Installation When it is not possible to meet the required vent terminal clearances of 12" (305mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178mm) below grade level. The 7" (178mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall. Ensure the sidewall venting clearances are observed.
10” (254mm) VENT CAP C B 12” (305mm) V H SEE CHART FOR PERMISSIBLE “H” AND “V” DIMENSIONS C 9” (229mm) minimum TO SIDE WALL B A CENTER OF ELBOW STRAIGHT OUT (MINIMUM) Figure 22 Figure 21 MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE FIREPLACE HARD ELBOW DIMENSIONS SERIES "A" "B" "C" DVX36FP 43-1/2" 5" 7" (1105mm) (127mm) (178mm) DVX42FP 43-1/2" 5" 7" (1105mm) (127mm) (178mm) FIREPLACE FLEX PIPE 90 DEGREE BEND SERIES "A" "B" "C
EXAMPLES - TOP VENT RUN 24” 24” MINIMUM CLEARANCE TO COMBUSTIBLES Example H2 3ft, H3 1ft = 4ft (90° + 90° + 90°) = 6ft V1 = 21ft H = 10ft V = 21ft Figure 25 Example H2 = 2ft 2 - (90° + 90°) = 6ft V1 = 21ft H = 8ft V = 15ft Figure 24 Example H1 = 2ft V1 = 20ft H = 2ft V = 20ft Figure 26 23835-4-0208 Page 17
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS CAUTION: Sharp edges, use protective gloves when installing. Tools Needed for Installation: Sheet metal snips 5/16” nut driver Phillips head screwdriver - #2 High temperature sealant or furnace cement rated for continuous use at 1,000oF minimum Measuring tape NOTE: SPACING FLANGE INSTALLED TO TOPSIDE 11” EXTENSION THIMBLE Parts Verification See parts list on page 20 to verify components included in this vent kit prior to installation.
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) 7. Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168mm) diameter tube from the opposite end. Do not crimp or enlarge tube. VINYL SIDING KIT DV822 OUTSIDE MOUNTING PLATE 8. Attach the 4” (102mm) diameter flue outlet tube onto the rigid venting system or directly to fireplace. Ensure the 4” (102mm) diameter flue outlet tube is placed as far as possible onto the rigid venting system.
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) Follow correct option according to venting method. Connecting Directly to Fireplace If the air inlet and flue outlet tubes are to be connected directly to the unit (no rigid venting system is being used), then the gasket provided must be used to seal the 4” (102mm) flue outlet tube. Peel the paper off the self-adhesive gasket and then wrap it around the end of the tube (if tube was cut, it is recommended to use cut end) as shown in Figure 31.
DVVK-4FV DIRECT VENT TERMINATION KIT Installation Instructions This termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use with DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your fireplace and verify the fireplace model number. Check that this flex vent system is listed for use with your fireplace model prior to starting the installation.
DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) PRE-INSTALLATION INFORMATION: Items Required For Installation: Tools Phillips Screwdriver Hammer Saw and/or saber saw Level Measuring Tape Electric Drill and Bits Pliers Square Tin Snips Building Supplies Framing Materials Wall Finishing Materials Caulking Material (Noncombustible) Support Strap supplies Before You Start: Plan your installation. Read these instructions and the fireplace installation manual before installing unit and vent system.
DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) Step-By-Step Installation For Flex DV Kit 1. 2. 3. 4. Unpack vent components and check all items for shipping damage. For this venting system to operate as designed it is dependent on the use of all parts and procedures detailed in these instructions. Failure to follow these instructions may potentially affect the performance of this vent system and the attached appliance.
DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) 10. With the flex vent assembly and the 48” long hard pipe components laid out on the floor, begin securing these parts together. First, apply a generous bead of silicone sealant to the inside of the 4” diameter flex flue (not the end with the pre-installaed connector), then slide the flex flue over the 4” diameter hard pipe flue. Be sure to overlap at least 1-1/4”. Secure this connection with a 4” diameter band clamp provided.
DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) 17. To attach the vent connections at the fireplace, be sure the 7” diameter adapter collar has been installed per step 3. Apply a bead of silicone sealant to the 4” diameter flex connector, then slide the flex pipe adapter collar into the fireplace flue collar and secure by installing a minimum of two (2) screws through the flue collar and into the adapter. See Figure 37. 18.
DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) VERTICAL TERMINATION STORM COLLAR 4’ LONG RIGID PIPE ROOF FLASHING ADJUSTABLE ROOF JACK ASSEMBLY ROOF EXTERIOR CLEARANCE TO COMBUSTIBLES REQUIRED FROM VENT PIPE CLAMPS AT FLUE & INLET VENT CONNECTIONS ADJUSTABLE FIRESTOP/THIMBLE ASSEMBLY CEILING STORM COLLAR (USE TO KEEP INSULATION OUT OF THIMBLE ASSEMBLY) FIRESTOP/THIMBLE VENTING SUPPORT STRAPS (AS REQ’D) 35’ MAX 4” DIA. FLUE CONNECTOR NOTE: DVVK-4FV KIT MAXIMUM HEIGHT (INCLUDING FIREPLACE) IS 13’.
DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) Vertical Flex Termination Kit Item Number 1 2 3 4 5 6 7 8 9 10 N/S N/S N/S N/S N/S 23835-4-0208 Item Description 4”/7” Vertical Termination Cap Roof Support Kit 2 Ply Alum Flex 4” Diameter by 6 ft. 2 Ply Alum Flex 7” Diameter by 6 ft.
DVVK-4F FLEX VENT INSTRUCTIONS The DVVK-4F FLEX VENT KIT includes the following components: • (1) 7" dia. Outer Vent adapter collar • (1) Horizontal Termination Cap • (1) Wall Firestop/Thimble Assembly • (1) 4-foot section of Flex vent with spacers (4" flue/7" outer • Hardware pack that includes band clamps and screws pipe) • (1) 4" dia. Flue adapter collar Flex venting can only be installed vertically off of the DVX Series fireplaces.
TERMINATION CLEARANCES Termination clearance for buildings with combustible and noncombustible exteriors.
VENT CLEARANCES VENT TERMINAL AREA WHERE TERMINAL IS NOT PERMITTED AIR SUPPLY INLET Figure 45 A= *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum] B= clearance to window or door that may be opened [*12 inches (30cm) minimum for appliances < 100,000 Btuh (30kW) C= clearance to permanently closed window [minimum 12 inches (30cm) recommended to prevent condensation on window] D= vertical clearance to ventilated soffit located above the terminal within a horizontal di
VENT SYSTEM IDENTIFICATION Installing Vent Components (Figure 46) Begin the vent system installation by installing the first Simpson Duravent component, 90° elbow to the starting collars or straight pipe on the top of the appliance, then the straight pipe length and then horizontal or vertical termination kit. NOTE: All outer connection joints must be sealed with aluminum tape, screws or silicone sealant rated above 300°F/149°C. The inner flue joints do not require any sealant.
VENTING FRAMING AND FINISHING Installing Support Brackets (Figure 47) A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance to combustibles above flue pipe and elbows and 1 inch clearance on both sides and bottom of the flue pipe to combustibles on all horizontal pipe sections and elbows.
VENTING FRAMING AND FINISHING (continued) EXISTING CEILING JOISTS NAILS, 4 REQUIRED CEILING FIRESTOP NEW FRAMING A A B B CEILING BELOW Vent Size A B Vent Size A B 6 5/8" 10" 10" 6 5/8" 10" 10" 8" 10 1/2" 10 1/2" 8" 10 1/2" 10 1/2" Figure 49 Figure 51 See Horizontal Termination Page 34 and Vertical Termination Pages 35 and 36.
HORIZONTAL TERMINATION NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap to its final exterior position on the building. Warning: Termination cap must be positioned so that arrow is pointing up. Attach the termination cap with the four wood screws provided. Before attachment of the termination, run a bead of silicone sealant rated above 250°F on its outside edge too, so as to make a seal to the exterior wall.
DVVK-5F FLEX VENT INSTRUCTIONS The DVVK-5F FLEX VENT KIT includes the following components: • (1) Horizontal Termination Cap • (1) Wall Firestop/Thimble Assembly • (1) 4-foot section of Flex vent with spacers (5" flue/8" • Hardware pack that includes band clamps and screws outer pipe) with flue adapter collar Flex venting can only be installed vertically off of the DVX Series fireplaces. When installing a horizontal vent run from top connections, maintain at least ½" rise for every 12" of vent run.
VERTICAL TERMINATION Locate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this nail through this center point. Make the outline of the roof hole around this center point. NOTE: Size of the roof hole dimensions depend on the pitch of the roof. There must be a 1 inch clearance (25mm) to the vertical pipe sections. This clearance is to all combustible material. Cover the opening of the vent pipe and cut and frame the roof hole.
VERTICAL TERMINATION (continued) FEMALE LOCKING LUG Figure 59 MALE LOCKING LUG CAUTION: Treatment of firestop spacers and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, your local building codes must be checked to determine the requirements for these steps.
LOG IDENTIFICATION REAR BOTTOM LOG (A) Part Number - R9228 REAR TOP LOG (B) Part Number - R9222 BOTTOM LEFT LOG (C) Part Number - R9227 BOTTOM LEFT CENTER LOG (D) Part Number - R9372 BOTTOM RIGHT CENTER LOG (E) Part Number - R9225 BOTTOM RIGHT LOG (F) Part Number - R9229 FRONT LEFT LOG (G) Part Number - R9223 CENTER LOG (H) Part Number - R9373 TOP LEFT LOG (I) Part Number - R-9230 TOP CENTER LOG (J) Part Number - R9231 TOP RIGHT LOG (K) Part Number - R9232 FRONT CENTER LOG (L) Part Number - R922
LOG PLACEMENT (13 LOG SET) Before you begin: If you are installing logs into the DVX36 or DVX42 model then this fireplace is supplied with a set of 13 ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fiber. 6. Place Bottom Left Log (C) on far left pin of burner. The "lip" of the log will hang off the side of the burner.
LOG PLACEMENT (13 LOG SET) 9. Place Bottom Right Log (F) on far right pin on the burner. The "lip" of the log will hang off the side of the burner. 10. Place Front Left Log (G) on (C) Log pin. End of (G) Log will rest on firebox bottom. 11. Place Center Log (H) on pin on (A) Log with "Y" branches resting on (D) and (E) logs. Page 40 12. Place Top Left Log (I) on two left pins on (B) Log. 13. Place Top Center Log (J) on third and fourth pins from the left on (B) Log. "Y" branch will rest on (H) Log. 14.
LOG PLACEMENT (13 LOG SET) 15. Place Front Center Log (L) between third and fourth grates on the burner. The short "Y" branch will point left and the bottom of the "Y" resting on the firebox bottom. 18. Replace glass door onto firebox. 19. Secure the two glass frame spring clamps at bottom of firebox. 20. Align the tabs on top louver brackets with slots in front posts to secure top louver. 21. Close bottom louver. Lift slightly to engage the end tabs into the slots in fireplace sides to close louver panel.
LOG PLACEMENT (13 LOG SET) J L I M B A C F E D K Figure 63 Index Letter A B C D E F G H I J K L M Page 42 H G Figure 64 Log Set Parts List Part Number Description R9228 Rear Bottom Log R9222 Rear Top Log R9227 Bottom Left Log R9372 Bottom Left Center Log R9225 Bottom Right Center Log R9229 Bottom Right Log R9223 Front Left Log R9373 Center Log R9230 Top Left Log R9231 Top Center Log R9232 Top Right Log R9224 Front Center Log R9226 Front Right Log 23835-4-0208
OPERATING INSTRUCTIONS 750 Millivolt System The standing pilot (750 millivolt system) is a continuous burning pilot. The pilot remains ON even when the main burner is OFF. The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas controls for the fireplace. When you ignite the pilot, the thermopile produces millivolts (electrical current) which energizes the magnet in the gas valve.
OPERATING INSTRUCTIONS (continued) STANDING PILOT OPERATING INSTRUCTIONS Remote/Off/On Switch The fireplace is equipped with a Remote/OFF/ON switch. A wire harness is attached to the Remote/OFF/ON switch. The red, black and green (wires) female push-ons attach to the Remote/OFF/ON switch. At the opposite end of the wire harness, the black and green (wires) female push-ons attach to the gas valve.
STANDING PILOT WIRING DIAGRAM REMOTE CONTROL RECEIVER (OPTIONAL) THERMOSTAT GAS VALVE (OPTIONAL) WALL SWITCH REMOTE/OFF/ON SWITCH (OPTIONAL) REMOTE CONTROL RECEIVER RED GREEN BLACK GREEN REMOTE/OFF/ON SWITCH REMOTE OFF ON THERMOPILE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH NO. 18, 150°C WIRE OR ITS EQUIVALENT.
STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. Before lighting smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken. 1. Spark ignitor will not light pilot after repeated triggering of piezo ignitor button. a. Defective ignitor (no spark electrode).
RF STANDING PILOT OPERATING INSTRUCTIONS Features • Self powered millivolt receiver/valve • Thermostat performance • Auto mode • Self powered millivolt control • Integrated Valve Electronics • Failure analysis • Pilotstat interlock • F or C temperature units Benefits • No external power or batteries required to operate valve and flame modulation • Flame cycles and modulates such that heat output equals heat loss from the room • Flame & fan are controlled automatically • No external power required to control
RF TRANSMITTER FUNCTIONS FIRST USE OF TRANSMITTER Status Action Begin communication between transmitter and receiver/valve. Move LOCAL/REMOTE Switch to LOCAL position for at least two seconds; then move switch to the REMOTE position. Transmit unique code. Press Fan or Flame key within 30 seconds. Confirm recognition between transmitter and receiver/valve. Observe LED turns on for one second. Chose Remote or Local operation. Move LOCAL/REMOTE switch to LOCAL or leave in REMOTE.
RF WIRING DIAGRAM WIRING DIAGRAM WITH BLOWER Figure 68 Page 50 23835-4-0208
RF STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas in heavier than air and will settle on the floor.
MAINTENANCE AND SERVICE Please Note It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. 3. Under no circumstances should this appliance be operated without the glass front or with a broken glass front. Replacement of the glass (with gasket) as supplied by the manufacturer should be done by a qualified service person. 4.
PARTS VIEW Note: Refer to page 42 when ordering logs.
PARTS LIST INDEX NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 29 30 31 32 33 34 35 35 36 37 38 39 PART NUMBER DVX36FP33CL DVX36FP93CL DVX42FP33CL DVX42FP93CL DESCRIPTION R9347 R9347 R9348 R9348 INSULATION, TOP SHIELD 23437 23437 23437 23437 TOP SHIELD 23219 23219 23219 23219 TOP STANDOFF (QTY. 2) R7566 R7566 R7567 R7567 VENT ADAPTER R7574 R7574 R7573 R7573 VENT GASKET 10554 10554 10554 10554 NAILING FLANGE (QTY.
PARTS LIST (continued) INDEX NO. 40 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 N/S PART NUMBER DVX36FP33CL DVX36FP93CL DVX42FP33CL DVX42FP93CL DESCRIPTION R7577 R6114 R7577 R6114 GAS VALVE (NAT) R7578 R6115 R7578 R6115 GAS VALVE (LPG) 17161 17796 17161 17796 GAS VALVE BRACKET 23502 23502 23502 23502 GRATE ASSEMBLY (QTY.
FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION Attention: Install blower assembly before connecting gas inlet supply line Note: Junction box on right side of fireplace must be pre-wired at time of fireplace installation for use with blower assembly. It is recommended that an ON/OFF wall switch be installed that will activate the power supply to the furnace by a qualified electrician. 1. 2. 3. 4. If installed, turn OFF gas supply to fireplace. If applicable, turn OFF electric supply to fireplace.
FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION JUNCTION BOX 1 FBB4 B L O W E R A S S E M B LY COMPLETE 2 R7649 FAN CONTROL 3 R4192 SPEED CONTROL KNOB 4 R4186 SPEED CONTROL 110 VOLT AC FAN BLACK FAN SWITCH WHITE SPEED CONTROL GROUND JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES.
ACCENT LAMP Your Luxury Direct Vent Gas Fireplace comes equipped with our "Accent Lamp." The light has been pre-wired and is controlled from the Rheostat. If in the event the lamp or lens needs to be replaced, follow the instructions below: 1. Unplug the Accent Lamp/transformer from the junction box inside the fireplace. 2. Remove the four screws that secure the lens frame. This frame retains the glass lens. The bulb can now be accessed.
ACCESSORIES The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220-2623.
HOW TO ORDER REPAIR PARTS Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment.