VENTING FIREPLACE (cont.)
Sidewall Venting
The maximum vertical and horizontal distances are 25 feet and 12
feet, respectively. Vertical dimensions are based on top of fireplace
to centerline of pipe. Horizontal dimensions are based on centerline
of pipe to termination.
CAUTION: Total vertical run MUST BE completed before
starting horizontal run. Horizontal chimney run must slope
upward (away from fireplace) 1/4" per foot and vent
termination must be level.
Under no circumstances should combustible materials (including
siding) be closer than 2" from the top of the 6 5/8" pipe or closer
than 1" on the side and bottom.
Cutting the Hole (Figure 7)
After the appliance has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This
hole needs to be 10" high x 10" wide square with its center line
determined by the amount of vertical arise and horizontal run of the
termination. When locating the hole it must be noted that the bottom
of the cap must be 12" above the ground level, and top of the cap
must be no less than 18" below a combustible projection, and no
closer than 9" to any wall running parallel to vent termination.
VENT CAP
9” (229MM) TO SIDE
WALL
Figure 7