Service manual
– 25 –
A unit P.M.V.
A unit 
send/receive
circuit
B unit 
send/receive
circuit
C unit 
send/receive
circuit
Clock frequency
oscillator circuit
16MHz
Clock frequency
oscillator circuit
10MHz
Outdoor 
fan 
motor
• Inverter outdoor frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• Error display
• Signal communication to MCU
• PWM synthesis function
M.C.U
• PWM synthesis function
• Input current release control
• IGBT over current detect control
• High power factor correction control
• Signal communication to MCU
• Output current release control
• A/D converter function
M.C.U
Discharge temp. SensorGas side pipe temp. SensorOutdoor air temp. Sensor
MCC-818 (SUB-P.C. B)
MCC-1438 (MAIN-P.C. B)
220–240V 
~
50Hz
220V 
~
60Hz
Driver
circuit of
P.M.V.
Signal communication
to MCU
Inverter
(DC   AC)
Over current
sensor
Compressor
B unit P.M.V.
C unit P.M.V.
Noise filter
Over current
sensor
Inverter
(DC   AC)
Output current
sensor
Input current
sensor
Converter
(AC   DC)
P.M.V : Pulse motor valve
PWM : Pulse width modulation
IGBT : Insulated gate bipolar
 transistor
Current detect 
circuit
Gate drive
circuit
Over current
detect circuit
High power factor
correction circuit
Over current
detect circuit
Gate drive
circuit
8-2. Outdoor Unit (Inverter Assembly)
RAS-3M23GACV-E