10-7-2. Miswiring (Mis-piping) Check by LED Indication
• For this outdoor unit, self-miswiring (mis-piping) checks are possible using the five LEDs (1 Yellow + 4 Red).
• LEDs (D800 to D804) are provided on the inverter P.C. board.
Fig. 10-7-2
LED
During check
Check results
D800 D801 D802 D803 D804
lllll
¥¥
lll
¥
l
¥
ll
¥
ll
¥
l
¥
¤
lll
¥
l
¤
ll
¥
ll
¤
l
¥
¤¤
ll
¥
¤
l
¤
l
¥
l
¤¤
l
¥
¤¤¤
l
Description
Normal operation (no error)
Checking A unit
Checking B unit
Checking C unit
Crush/Clog of pipe A
Crush/Clog of pipe B
Crush/Clog of pipe C
Miswiring/Mis-piping or Crush/Clog of pipe A, B
Miswiring/Mis-piping or Crush/Clog of pipe A, C
Miswiring/Mis-piping or Crush/Clog of pipe B, C
A, B, C Miswiring/Mis-piping
LED : Light Emitting Diode,
¤
: LED ON,
l
: LED OFF,
¥
: LED Flash