2-2. Specifications of Performance When Each Indoor Unit is Combined with Other Unit
Indoor unit Unit ca
p
acit
y
(
kW
)
O
p
eratin
g
status
Power
su
pp
l
y
(V)
ABCABC
Cooling
capacity
(kW)
Power
consum
tion
(W)
Operation
current
(A)
Outdoor
noise
(dB)
220 10 ——2.7 ——
2.7
(1.4 to 3.2)
770
(320 to 950)
4.12
(
2.08 to 5.08
)
45
230 10 ——2.7 ——
2.7
(1.4 to 3.2)
770
(320 to 950)
3.94
(
1.99 to 4.86
)
45
240 10 ——2.7 ——
2.7
(1.4 to 3.2)
770
(320 to 950)
3.77
(
1.90 to 4.66
)
45
220 13 ——3.7 ——
3.7
(1.4 to 4.4)
1200
320 to 1470
6.34
(
2.08 to 7.51
)
48
230 13 ——3.7 ——
3.7
(1.4 to 4.4)
1200
320 to 1470
6.07
(
1.99 to 7.18
)
48
240 13 ——3.7 ——
3.7
(1.4 to 4.4)
1200
320 to 1470
5.81
(
1.90 to 6.88
)
48
220 16 ——4.5 ——
4.5
(1.4 to 4.9)
1600
320 to 1750
7.66
(
2.08 to 8.37
)
48
230 16 ——4.5 ——
4.5
(1.4 to 4.9)
1600
320 to 1750
7.32
(
1.99 to 8.01
)
48
1 unit
240 16 ——4.5 ——
4.5
(1.4 to 4.9)
1600
320 to 1750
7.02
(
1.90 to 7.68
)
48
220 10 10 2.7 2.7
5.4
(1.8 to 6.0)
1500
360 to 1880
7.18
(
2.34 to 9.00
)
48
230 10 10 2.7 2.7
5.4
(1.8 to 6.0)
1500
360 to 1880
6.86
(
2.24 to 8.60
)
48
240 10 10 2.7 2.7
5.4
(1.8 to 6.0)
1500
360 to 1880
6.58
(
2.14 to 8.25
)
48
220 10 13 2.45 3.35
5.8
(1.8 to 6.3)
1800
360 to 1970
8.61
(
2.34 to 9.43
)
48
230 10 13 2.45 3.35
5.8
(1.8 to 6.3)
1800
360 to 1970
8.24
(
2.24 to 9.02
)
48
240 10 13 2.45 3.35
5.8
(1.8 to 6.3)
1800
360 to 1970
7.89
(
2.14 to 8.64
)
48
220 10 16 2.21 3.69
5.9
(1.8 to 6.4)
1830
360 to 2000
8.76
(
2.34 to 9.57
)
48
230 10 16 2.21 3.69
5.9
(1.8 to 6.4)
1830
360 to 2000
8.38
(
2.24 to 9.15
)
48
240 10 16 2.21 3.69
5.9
(1.8 to 6.4)
1830
360 to 2000
8.03
(
2.14 to 8.77
)
48
220 13 13 2.95 2.95
5.9
(1.8 to 6.4)
1830
360 to 2000
8.76
(
2.34 to 9.57
)
48
230 13 13 2.95 2.95
5.9
(1.8 to 6.4)
1830
360 to 2000
8.38
(
2.24 to 9.15
)
48
240 13 13 2.95 2.95
5.9
(1.8 to 6.4)
1830
360 to 2000
8.03
(
2.14 to 8.77
)
48
220 13 16 2.71 3.29
6.0
(1.8 to 6.4)
1850
360 to 2000
8.85
(
2.34 to 9.57
)
48
230 13 16 2.71 3.29
6.0
(1.8 to 6.4)
1850
360 to 2000
8.50
(
2.24 to 9.15
)
48
240 13 16 2.71 3.29
6.0
(1.8 to 6.4)
1850
360 to 2000
8.11
(
2.14 to 8.77
)
48
220 16 16 3.05 3.05
6.1
(1.8 to 6.5)
1870
360 to 2050
8.95
(
2.34 to 9.81
)
48
230 16 16 3.05 3.05
6.1
(1.8 to 6.5)
1870
360 to 2050
8.56
(
2.24 to 9.38
)
48
2 inits
240 16 16 3.05 3.05
6.1
(1.8 to 6.5)
1870
360 to 2050
8.20
(
2.14 to 8.99
)
48
220 10 10 10 2.13 2.13 2.13
6.4
(2.2 to 7.0)
1880
420 to 2300
9.00
(
2.73 to 11.0
)
48
230 10 10 10 2.13 2.13 2.13
6.4
(2.2 to 7.0)
1880
420 to 2300
8.60
(
2.61 to 10.53
)
48
240 10 10 10 2.13 2.13 2.13
6.4
(2.2 to 7.0)
1880
420 to 2300
8.25
(
2.50 to 10.09
)
48
220 10 10 13 1.99 1.99 2.72
6.7
(2.2 to 7.0)
2150
420 to 2300
10.29
(
2.73 to 11.0
)
48
230 10 10 13 1.99 1.99 2.72
6.7
(2.2 to 7.0)
2150
420 to 2300
9.84
(
2.61 to 10.53
)
48
240 10 10 13 1.99 1.99 2.72
6.7
(2.2 to 7.0)
2150
420 to 2300
9.43
(
2.50 to 10.09
)
48
220 10 13 13 1.80 2.45 2.45
6.7
(2.2 to 7.0)
2150
420 to 2300
10.29
(
2.73 to 11.0
)
48
230 10 13 13 1.80 2.45 2.45
6.7
(2.2 to 7.0)
2150
420 to 2300
9.84
(
2.61 to 10.53
)
48
240 10 13 13 1.80 2.45 2.45
6.7
(2.2 to 7.0)
2150
420 to 2300
9.43
(
2.50 to 10.09
)
48
220 10 10 16 1.83 1.83 3.04
6.7
(2.2 to 7.0)
2150
420 to 2300
10.29
(
2.73 to 11.0
)
48
230 10 10 16 1.83 1.83 3.04
6.7
(2.2 to 7.0)
2150
420 to 2300
9.84
(
2.61 to 10.53
)
48
3 units
240 10 10 16 1.83 1.83 3.04
6.7
(2.2 to 7.0)
2150
420 to 2300
9.43
(
2.50 to 10.09
)
48
The above specification values are those under the conditions that the indoor DB/WB = 27/19°C and the outdoor
DB = 35°C.