Service manual
– 70 –
Turn off power 
supply once, and 
turn it on again.
Start to operate 
indoor unit in cooling 
operation at airflow 
level “LOW”.
Turn off indoor unit and 
remove connector from motor.
Then start to operate indoor 
unit with remote controller.
Turn off indoor unit and remove 
connector from motor.
Then push START/STOP button 
on remote controller to stop 
flashing lamp on indoor unit.
Change airflow level 
to “HIGH”.
Turn off indoor unit 
and rotate cross-flow 
fan by hand when the 
unit is on standby.
At this time, is it possible to 
detect DC 1V or more 
between 
5
+
 and 
3
 – 
of motor connector 
(CN10).
Start to operate the 
indoor unit in except 
heating operation.
At this time, is it possible 
to detect DC 1V or more 
between 
5
+
 and 
3
 – 
of motor connector (CN10)?
(Check this condition 
within 15 seconds after 
starting unit.)
Start to operate the 
indoor unit in except 
heating operation.
At this time, is it possible to 
detect DC 1V or more between 
5
+
 and 
3
 – of motor 
connector (CN10)?
Is it possible to detect 
DC 1V or more between 
5
+
 and 
3
 – of 
motor connector (CN10).
Is it possible to detect 
DC 310–340V between 
1
+
 and 
3
 – of motor 
connector (CN10).
(Motor connection condition)
Is it possible to detect DC 15V 
between 
4
+
 and 
3
 – of 
motor connector (CN10).
Is it possible to detect 
DC 15V between 
4
+
and 
3
 – of motor 
connector (CN10).
Is it possible to 
change airflow level 
to “HIGH”?
Is it possible to 
rotate cross-flow fan by 
hand properly?
Does fan motor 
continue to operate?
Does indoor 
fan operate?
Fan motor 
operates normally.
Replace indoor 
fan motor.
Replace main 
P.C. board.
Replace 
bearing.
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
(3) Only the indoor motor fan does not operate
<Primary check>
1. Is it possible to detect the power supply voltage (AC220–240V) between 
 and 
 on the terminal block?
2. Does the indoor fan motor operate in cooling operation?
(In heating operation, the indoor fan motor does not operate for approximately 10 minutes after it is turned
on, to prevent a cold air from blowing in.)