Install Manual
Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.
Some models also include an adaptor plate to cover unpainted
surfaces. Thermostat wires pass through the adaptor plate
center opening.
1. Remove Old Thermostat: A standard heat/cool thermostat
consists of three basic parts:
a. The cover, which may be either a snap-on or hinge type.
b. The base, which is removed by loosening all captive screws.
c. The switching subbase, which is removed by
unscrewing the mounting screws that hold it on the wall
or adaptor plate.
Make a note here of the anticipator setting
on the old thermostat for future reference and use in step 5.
The heat anticipator pointer, if adjustable, will be set at one of a
series of numbers representing the current rating of the primary
control in your furnace. The number will be one of the following:
.2, .4, .8, etc. or 0.2, 0.4, 0.8, etc.
If no heat anticipator/indication is showing, do not be concerned;
move on to the next step.
THERMOSTAT FEATURES
2
REMOVING OLD THERMOSTAT
3
To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.
CAUTION
!
1C20 – Heating Only
1C26 – Heating & Cooling
INSTALLATION AND OPERATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Operator: Save these instructions for future use!
YOUR THERMOSTAT REPLACES
Description 1C20 1C26
Standard Heating & Cooling Systems - 4 or 5 wires No Ye s
Standard Heat Only Systems Ye s Ye s
Millivolt Heat Only Systems - Floor or Wall Furnaces Ye s Ye s
Standard Central Air Conditioning No Ye s
Gas or Oil Heat Ye s Ye s
Electric Furnace Ye s Ye s
Hydronic (Hot Water) Zone Heat - 2 Wires Ye s Ye s
Hydronic (Hot Water) Zone Heat - 3 Wires No No
Heat Pump (No Aux or Emergency Heat) No Ye s
Heat Pump (with Aux or Emergency Heat) No No
Baseboard Electric Heating or Line Voltage (120 or 240 Volt) No No
white-rodgers.com
emersonclimate.com
PART NO. 37-6335C
Replaces 37-6335B
1640
SUBBASE
(MODEL 1C26
ONLY)
BASE
COVER
ANTICIPATOR
CAPT
IVE SCREWS
MOUNTING SCREWS
Figure 1.
SUBBASE
(MODEL 1C26
ONLY)
BASE
COVER
ANTICIPATOR
CAPTIVE SCREWS
MOUNTING SCREWS
Figure 1.
Adaptor Plate
(optional)
Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage
Assemble tools required as shown below.
PREPARATIONS
1
WIRE CUTTER/STRIPPER
SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL—
THERMOSTAT MUST BE LEVEL TO WORK PROPERLY
FLAT BLADE SCREWDRIVER
HAND OR PO
WER
DRILL
WITH 3/16 INCH
DRILL BI
T, IF NEEDED