Competitive Cross Reference

www.white-rodgers.com
81
FURNACE
Original Original Suggested
O.E.M. Capillary Panel Replacement
Number Length Types Type Number
3049-1 30 or 48 A 3049-5
3049-3 26 A 3049-3
3049-4 33 A 3049-4
3049-5 48 B 3049-5
3049-6 12 B 3049-5
3049-7 24 B 3049-5
3049-11 24 B None
3049-15 33 A 3049-15
3049-18 30 or 33 D 3049-18
3049-20 42 B None
3049-29 20 B 3049-4
3049-31 12 B None
3049-32 12 B None
3049-33 24 B None
3049-36 48 B 3049-5
3049-37 30 B 3049-5
3049-41 24 or 48 B 3049-41
3049-49 42 B 3049-64
3049-52 30 B, D 3049-115
3049-54 30 B 3049-115
3049-55 30 A, D 3049-115
3049-58 30 B 3049-64
TYPES WITH SPADE TERMINALS
Original Original Suggested
O.E.M. Capillary Panel Replacement
Number Length Types Type Number
3049-59 30 B None
3049-61 24 B 3049-64
3049-62 18 B None
3049-64 48 D 3049-64
3049-66 30 B 3049-115
3049-68 30 B 3049-115
3049-70 30 B None
3049-71 30 B 3049-4
3049-72 30 E None
3049-101 24 B None
3049-105 42 B 3049-115
3049-106 24 D 3049-115
3049-107 12 B, D 3049-115
3049-111 24 B, D 3049-115
3049-112 18 B, D 3049-115
3049-114 30 D 3049-115
3049-115 48 D 3049-115
3049-119 24 B 3049-115
3049-120 30 B 3049-115
3049-121 18 or 42 B 3049-115
3049-537 30 B None
3049-561 24 B None
Original Original Suggested
O.E.M. Capillary Panel Replacement
Number Length Types Type Number
3094-102 30 C 3094-118
3094-111 30 C None
3094-118 48 C 3094-118
3094-122 30 C None
3094-123 30 G 3094-123
3094-127 48 C 3094-118
3094-131 22 C None
3098-111 30 E 3098-134
3098-117 24 E None
3098-120 30 E None
3098-122 30 E 3098-156
3098-126 30 E 3098-156
3098-127 24 E 3098-156
3098-130 24 E 3098-156
3098-131 30 E 3098-156
3098-134 48 E 3098-134
3098-135 48 E None
3098-136 30 E 3098-134
3098-137 12 E None
3098-139 36 E None
PLUG-IN TYPES
Original Original Suggested
O.E.M. Capillary Panel Replacement
Number Length Types Type Number
3098-141 48 E 3098-134
3098-142 30 E 3098-156
3098-143 36 E 3098-156
3098-147 18 E 3098-134
3098-148 48 E None
3098-149 24 or 42 E 3098-156
3098-151 26 or 33 E None
3098-153 24 E 3098-156
3098-156 48 E 3098-156
3098-161 24 or 30 E 3098-134
3098-165 48 E 3098-134
3098-168 48 E 3098-156
3098-169 27 E 3098-134
3098-171 30 or 42 E 3098-156
3094-174 36 E 3098-156
3098-175 18 E 3098-156
3098-177 24 E None
3098-178 30 E None
3098-182 24 or 42 E 3098-156
3098-183 12 E None
3098-184 42 E 3098-134
3098-522 30 E 3098-522
3098-536 30 E None
Consult the O.E.M. for replacement type number
Suggested replacement type may have different panel conguration. Some controls experienced
modication. Determine proper wiring with the aid of panel diagrams A through G.
Note: Panel type C features an Electrical Quick Shut-Off Resistor (see diagram)
MERCURY FLAME SENSOR
CROSS REFERENCE
FLAME SENSORS
Model Type Valve Cap
Number Gas Type Terminations Length Comments
3046-5 Natural Screw 48 Recycling
30A46-5 Natural Plug-in 48 Recycling
FLAME SENSORS
Screw terminals inside cover switch-case for use with any standard 24/120/240 VAC solenoid or diaphragm
gas valve
Plug-in switch-case for use with White-Rodgers “Silent Knight” (25G01 series) and “Cushioned Power”
(25D46 series) solenoid valves
Types 3046-5 and 30A46-5 can be used on LP gases only if an external means for automatic pilot gas
shut-off is provided
30A46-5
CONTRACTOR TIP: Mercury ame sensors can only be replaced by cross referencing the
original mercury ame sensor model number. They can not be replaced by gas valve model
number.