Brochure

www.white-rodgers.com
79
FURNACE
MERCURY FLAME SENSORS
Prevent Gas Flow to Main Burner if Pilot Flame is Not Burning or Is
Insufcient to Properly Ignite Main Burner
FEATURES
These sensors combine a rugged Snap-Action switch and powerful mercury
actuated thermal element.
May be used with natural, manufactured or mixed gases and with LP gases where
means are provided for obtaining automatic pilot gas shut-off.
Switch may be conveniently mounted in any position.
Cover is easily removed, making switch terminals readily accessible.
No button to depress – Sensors are recycling type which require relighting or
possible restoration of proper gas pressure to return to operation.
SPECIFICATIONS
Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . Contacts close approximately 60 seconds
after pilot is ignited; open approximately
40 seconds after ame is extinguished
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. recognized and C.S.A. certied,
A.G.A. design certied & C.G.A. certied
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . 2
3
/
4
H x 2
1
/
16
W x 1
7
/
8
D
Model Element Electrical Rating
Number Length 120 VAC 240 VAC 30 VAC
3046-5 48 125 VA 125 VA 90 VA
PLUG-IN TYPE MERCURY FLAME SENSORS
Designed for use with White-Rodgers Diaphragm, “Cushioned Power”
or “Silent Knight” Gas Valves having Plug-In Receptacle
FEATURES
Plug-in feature requires no additional electrical connections or mounting devices.
Sensor combines a rugged Snap-Action SPDT switch and powerful mercury
actuated thermal element.
May be used with natural, manufactured or mixed gases and with LP gases where
means are provided for obtaining automatic pilot gas shut-off.
No button to depress – Sensors are recycling type which require relighting or
possible restoration of proper gas pressure to return to operation.
The SPDT switch can energize ignitor circuit to relight pilot (as with roof top units).
SPECIFICATIONS
Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . Contacts close approximately 60 seconds
after pilot is ignited; open approximately
40 seconds after ame is extinguished
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. recognized, A.G.A. design certied
and C.G.A. certied
Model Element Electrical Rating
Number Length 120 VAC 240 VAC 30 VAC Comments
30A46-5 48 125 VA 125 VA 90 VA stud mount element
30A46-105 12 125 VA 125 VA 90 VA sleeve over element,
no stud mount
30A46-5