36C STANDING PILOT SNAP OPEN, STEP OPEN, HSI,
DSI, AND INTERMITTENT IGNITION GAS VALVES
A Wide Range of Replacement Valves for the Professional Installer
SPECIFICATIONS
Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . 0.23 amps
Ambient Operating Range ................ -40 to +175°F (-40 to 79°C)
Maximum Pressure Rating ................
1
/
2
PSI (14.0 W.C.)
Pilot Gas Connection ....................
1
/
4
compressiontting
Pressure Tap ..........................
1
/
8
N.P.T.
36C Series
PARTS AND ACCESSORIES
See end of this section for parts and accessories
36C SERIES
GAS VALVE
GAS BURNER
CONTROLS
STD. NAT GAS LP GAS STD. NAT GAS LP GAS
Pipe Size 1000 BTU/CU. FT. 2500 BTU/CU. FT. 1000 BTU/CU. FT. 2500 BTU/CU. FT.
1/2 X 3/8 100,000 162,000 15,000-100,000 15,000-162,000
1/2 X 1/2 230,000 372,600 30,000-290,000 30,000-469,000
1/2 X 3/4 230,000 372,600 30,000-290,000 30,000-469,000
3/4 X 3/4 280,000 453,600 50,000-400,000 50,000-648,000
1” Pressure Drop Capacity Rated Range of Regulation
BTU/HR BTU/HR
Universal
Universal
Wiring diagrams – see pages 171-174
Indicates Canadian Model Number
SNAP OPEN, SINGLE FUNCTION, STANDING PILOT GAS VALVES
36C74-913 Step 24VAC Natural
3
/
4
x
3
/
4
Step 0.9/3.5 2.5-5.0 No No No Str. Thru Yes Yes No 5
Open
36C94-303 24VAC
1
/
2
x
3
/
4
Delay
3.5 2.5-5.0 Yes Yes No Str. Thru No Yes No 15
Slow 7.0-12.0
HSI/DSI VALVES
Intermit-
tent
Ignition
Systems
?
WIRIING
171-174
LP Internal
Opening Regulator Conversion Reducer Inlet Wiring
Model Typical Coil Gas Pipe Character- Regulator Adjustment Convertible Kit Line Flow Bushing Pressure Side See
Number App. Voltage Type Size ristic Setting Range Nat. / LP Included Interrupter Direction Kit Tap Taps Figure
36C01-405 Snap 24VAC
3
/
4
x
3
/
4
Fast Open 3.5 2.5-5.0 Yes Yes No Str. Thru Yes No No 1
Open
36C01A-405 Snap 120VAC
3
/
4
x
3
/
4
Fast Open 3.5 2.5-5.0 Yes Yes No Str. Thru Yes No No 3
Open
36C03-300
Standing 24VAC
1
/
2
x
3
/
4
Fast Open 3.5 2.5-5.0 Yes Yes Yes Str. Thru Yes No No 1
Pilot
36C03-333 Standing 24VAC
1
/
2
x
3
/
4
Fast Open 3.5 2.5-5.0 Yes Yes Yes Str. Thru Yes No Yes 1
Pilot
36C03-400 Standing 24VAC
3
/
4
x
3
/
4
Fast Open 3.5 2.5-5.0 Yes Yes Yes Str. Thru Yes No No 1
Pilot
36C03-433 Standing 24VAC
3
/
4
x
3
/
4
Fast Open 3.5 2.5-5.0 Yes Yes Yes Str. Thru Yes Yes Yes 1
Pilot
36C03A-410 Standing 120VAC
3
/
4
x
3
/
4
Fast Open 3.5 2.5-5.0 Yes Yes Yes Str. Thru Yes No No 3
Pilot
36C03U-333 Standing 750mV
1
/
2
x
3
/
4
Fast Open 3.5 2.5-5.0 Yes Yes Yes Str. Thru Yes Yes Yes 2
Pilot
36C03U-433 Standing 750mV
3
/
4
x
3
/
4
Fast Open 3.5 2.5-5.0 Yes Yes Yes Str. Thru Yes Yes Yes 2
Pilot
36C04U-438 Standing 750mV Natural
3
/
4
x
3
/
4
Step Open 0.7 / 3.5 2.5-5.0 No No Yes Str. Thru Yes No No 2
Pilot 0.7
36C53-418
Standing 24VAC
3
/
4
x
3
/
4
Slow Open 3.5 2.5-5.0 Yes No Yes Str. Thru Yes No No 1
Pilot
36C03-258 Standing 24VAC Natural
1
/
2
x
1
/
2
Fast Open 3.5 2.5-5.0 No No Yes Str. Thru No Yes No 1
Pilot
Natural
or
LP
Natural
or
LP
Natural
or
LP
Natural
or
LP
Natural
or
LP
Natural
or
LP
Natural
or
LP
Natural
or
LP
Natural
or
LP
Natural
or
LP
Natural
or
LP
HEATING
www.white-rodgers.com
35

Summary of content (1 pages)