Install Instructions

36C/36D
HSI, DSI Proven Pilot Gas Valves
PART NO. 37-6516A
0646
INSTALLATION INSTRUCTIONS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
The 36C/36D series HSI, DSI proven pilot gas valves are
for use on Spark or Hot Surface Ignition systems and
replaces many O.E.M. gas valves. These valves may be
mounted in any position except upside down. Inlet screen
and pilot gas filter provide maximum protection against
chips and dirt. ON/OFF switch and regulator adjustment
(on some models) are on top of valve for quick setup. Large,
easy-grip pipe boss speeds installation.
Wiring diagrams – see pages 4 & 5
LP Internal
Regulator Conversion Reducer Inlet Wiring
Model Coil Gas Pipe Opening Regulator Adjustment Convertible Kit Line Flow Bushing Pressure Side See
Number Voltage Type Size Characteristic Setting Range Nat./LP Included Interrupter Direction Kit Tap Taps Figure
36C74-913 24 VAC Natural
3
/
4
x
3
/
4
Step 0.9/3.5 2.5–5.0 No No No Str. Thru Yes Yes No 3
36C76-906 24 VAC Natural
3
/
4
x
3
/
4
2 Stage 1.0/3.5 2.5–5.0 No No No Str. Thru No Yes No 5
Bimetal,
Electric Open
36C76-920 24 VAC Natural
3
/
4
x
3
/
4
2 Stage 1.3/3.5 2.5–5.0 No No No Str. Thru No Yes No 5
Bimetal,
Electric Open
36C76-962 24 VAC LP
3
/
4
x
3
/
4
2 Stage 5.0/11.0 9.0–12.0 No No No Str. Thru No No No 5
Bimetal,
Electric Open
36C76-963 24 VAC Natural
3
/
4
x
3
/
4
2 Stage 2.0/3.5 2.5–5.0 No No No Str. Thru Yes Yes No 5
Bimetal,
Electric Open
36D13-508 24 VAC Natural
1
/
2
x
1
/
2
2 Stage 1.1/3.5 Non- No No No Str. Thru No No No 6
Relay, Adjustable
Electric Open
Lo 1.1/Hi 3.5
36D13-905 24 VAC Natural
3
/
4
x
3
/
4
2 Stage 1.1/3.5 2.5–5.0 No No No Str. Thru No No No 6
Relay,
Electric Open
Lo 1.1/Hi 3.5
36D13-914 24 VAC LP
3
/
4
x
3
/
4
2 Stage 2.5/11.0 Non- No No No Str. Thru No No No 6
Relay, Adjustable
Electric Open
Lo 2.5/Hi 11.0
LP Internal
Regulator Conversion Reducer Inlet Wiring
Model Coil Gas Pipe Opening Regulator Adjustment Convertible Kit Line Flow Bushing Pressure Side See
Number Voltage Type Size Characteristic Setting Range Nat./LP Included Interrupter Direction Kit Tap Taps Figure
36C68-923 24 VAC Natural
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 Yes Yes No Str. Thr u Yes No No 3
UNIVERSAL ELECTRONIC IGNITION GAS VALVES One Model Fits Most Applications
Indicates Canadian Model Number
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com

Summary of content (8 pages)