Brochure

LP Internal
Regulator Conversion Reducer Inlet Outlet Wiring
Model Coil Gas Pipe Opening Regulator Adjustment Convertible Kit Flow Bushing Filter Pressure Pressure See
Number Voltage Type Size Characteristic Setting Range Nat. / LP Included Direction Kit Screen Tap Taps Figure
36J22-214* 24 VAC
1
/
2
x
1
/
2
Fast Opening 3.5 Nat. 2.5- 5.0 Yes Yes Str. Thru Yes Yes Yes Yes 1
L.P. 7.0- 12.0
36J24-214* 24 VAC
1
/
2
x
1
/
2
Slow Opening 3.5 Nat. 2.5- 5.0 Yes Yes Str. Thru Yes Yes Yes Yes 1
L.P. 7.0- 12.0
36J54-214* 24 VAC
1
/
2
x
1
/
2
2 Stage LO 1.5 Nat. 2.5- 5.0 Yes Yes Str. Thru Yes Yes Yes Yes 2
Fast Opening HI 3.5” L.P. 6.0- 12.0
36J55-214* 24 VAC
1
/
2
x
1
/
2
2 Stage LO 1.5 Nat. 2.5- 5.0 Yes Yes Str. Thru Yes Yes Yes Yes 2
Slow Opening HI 3.5 L.P. 6.0- 12.0
36J24-614* 24 VAC
1
/
2
x
1
/
2
2 Stage 3.5 Nat. 2.5- 5.0 Yes Yes No Yes Yes Yes 2
Slow Opening L.P. 7.0- 12.0
36J55-614* 24 VAC
1
/
2
x
1
/
2
2 Stage 3.5 Nat. 2.5- 5.0 Yes Yes No Yes Yes Yes 2
Slow Opening L.P. 6.0- 12.0
36J SERIES GAS VALVES
The 36J is a Combination Gas Control Valve Designed for use with
Non-Piloted Intermittent Ignition Systems. The Control is Designed to
meetToday’sMaximumCapacity,SmallerSizeandHighEfciency
Gas Systems.
FEATURES
•Inletandoutletscreens.
•Quietredundant.
•Built-inpressuretap.
•Quick-connectterminals(
1
/
4
).
SPECIFICATIONS
Ambient Temperature ................ -40 to 175°F
Maximum Pressure Rating ............
1
/
2
PSI (14.0 W.C.)
Capacity (1 P.D.)................... Natural 140,000 Btu/Hr.
L.P. 226,800 Btu/Hr.
Electrical Rating . . . . . . . . . . . . . . . . . . . . Single stage 24V, 50 / 60Hz at .3A
Two stage at .43A
Swing Radius . . . . . . . . . . . . . . . . . . . . . . 2.75
Mounting.......................... Any position
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . C.S.A. approved
36J SERIES
GAS VALVES
GAS BURNER
CONTROLS
1 Pressure Drop Capacity Range of Regulation
BTU/HR BTU/HR
Std Gas LP Gas Std Gas LP Gas Adjustment Adjustment
Valve .64 Sp. Gr. 1.53 Sp. Gr. .64 Sp. Gr. 1.53 Sp. Gr. Range Range
(Stages) Pipe Size (1000 BTU/CU. FT.) (2500 BTU/FT.) (1000 BTU/CU. FT.) (2500 BTU/FT.) (Nat. IN. W.C.) (L.P. IN. W.C.)
Single 1/2 x 1/2NPT 140,000 BTU/HR 226,800 BTU/HR 40,000-210,000 60,000-340,000 2.5-5.0 7.0-12.0
Two 1/2 x 1/2NPT 140,000 BTU/HR 226,800 BTU/HR 20,000 Low- 32,000 Low- 1.0-4.0Low 4.0-10.0Low
210,000 High 340,000 High 2.0-5.0High 6.0-12.0High
PARTS AND ACCESSORIES See end of this section for parts and accessories
TECHNICAL HELP
Wiring Diagrams...................... See page 177
?
36J Series
*Tomeasureoutletpressureonvalves,loosenoutletpressuretapscrewonequarterturnandputmanometerhoseoverthetopoftheoutletpressuretap.