Instructions / Assembly

2
INSTALLATION
OEM REPLACEMENT INSTRUCTIONS - 50M56U-801
Lennox Model
Furnace using
control:
NOTE: Ignitor must be replaced with
120V Ignitor
(Recommend 21D64-2) 75M21 Ignitor
- Remove existing control and verify
part number to be replaced
- Reference Wiring diagram
- Install harness 0115-0303 into the
Inducer and Ignitor 4-pin connector
- Plug in remaining connections
81W03
1012-969A
17W70
100973-01,02
1012-969
78M4701
78M1701
75M1701
Lennox,
Armstrong,
Ducane
Furnaces
using control:
- Remove existing control and verify
part number to be replaced
- Reference Wiring diagram
- Plug in all connections.
56W19
94W83
R47582-001
103085-01
1012-967
103085-02
103085-03
1012-83-9673A
1012-977A
81W11
56L8501
12L4201
50A55-120
80M2701
1012-968
Lennox Model
Furnace using
control:
- Remove existing control and verify
part number to be replaced
- Reference Wiring Diagram
- Install harness 0115-0303 into the
Inducer and Ignitor 4-pin connector.
- Install harness 0115-0302 into the
main 12-pin connector.
- Plug in remaining connections.
74W03
103098-01
1195-100
1195-83-100A
Follow Appliance Manufacturer’s recommended installation
or service instructions to ensure proper operation after
installation
All installation procedures should be carried out ONLY
by a qualified Heating and Air Conditioning contractor
or licensed electrician, according to Local and National
Electrical codes and Ordinances.
WARNING
!
FIRE HAZARD
Do not exceed the specified voltage.
Replace existing control with exact model and dash
number.
Protect the control from direct contact with water
(dripping, spraying, rain, etc.).
If the control has been in direct contact with water,
replace the control.
Label all wires before disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation.
Route and secure wiring away from flame.
SHOCK HAZARD
Disconnect electric power before servicing.
Ensure proper earth grounding of appliance.
Ensure proper connection of line neutral and line hot
wires.
EXPLOSION HAZARD
Shut off main gas to appliance until installation is
complete.
WARNING
!
Failure to comply with the following warnings could
result in personal injury or property damage.