Brochure

www.white-rodgers.com
119a
TYPE 70 SPNO
Single Pole Normally Open Contact
Case is Dust Resistant and Isolated from Ground
SPECIFICATIONS
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . 2.47L x 3.48W x 2.40H
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 oz.
Temperature Range . . . . . . . . . . . . . . . . . . . -40° to +122°F
Terminations, Contacts. . . . . . . . . . . . . . . . .
5
/
16
-24 UNF-2A thread
Terminations, Coil. . . . . . . . . . . . . . . . . . . . . #10-32 UNF-2A thread
Recommended Mounting . . . . . . . . . . . . . . . . . . . Plunger vertical with cap down
Hardware Torque, Contact Terminal. . . . . . . . . . . 45-55 in. lbs.
Hardware Torque, Coil Terminal . . . . . . . . . . . . . . 12-18 in. lbs.
Caution: A back-up wrench must be used to hold the bottom nut stationary.
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. 538 Recognized, File AU2138
Coil Coil Contact Rating (Amps) – Inductive Load
Model Duty Terminal Pole Bracket Voltage Resistance Contact Voltage Normally Open Normally Closed
Number Cycle Type Form Style D.C. (Ohms) Material D.C. Continuous Inrush Continuous Inrush
70-111225 Continuous 3A SPNO Standard 12 16 Copper 12 80 400 60 60
70-111224 Continuous 4 SPNO Standard 12 16 Copper 12 80 400 60 60
70-117224 Continuous 4 SPNO Standard 24 60 Copper 24 50 50 30 30
70-120224 Continuous 4 SPNO Standard 36 114 Copper 36 50 50 30 30
“3A” = Coil Grounded to Case
“4” = Isolated Coil
Coil resistance in Ohms @ 25°C
Intermittent duty designs available.
TYPE 120 SPNO
Single Pole Normally Open Contact, Dust Resistant, Water Resistant
and Case is Isolated from Bracket
SPECIFICATIONS
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 2.13L x 2.88W x 3.09H (Std. Bracket)
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 2.50L x 3.00W x 3.03H (L-Shaped Bracket)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 oz.
Temperature Range, Intermittent Duty . . . . . -20° to +150°F
Temperature Range, Continuous Duty . . . . . -20° to +120°F
Terminations, Contacts. . . . . . . . . . . . . . . . .
5
/
16
-24 studs, .495 min. length
Terminations, Coil. . . . . . . . . . . . . . . . . . . . . #10-32, .451 min. length
Recommended Mounting . . . . . . . . . . . . . . . . . . . Coil terminals up or horizontal
Hardware Torque, Contact Terminal. . . . . . . . . . . 45-55 in. lbs.
Hardware Torque, Coil Terminal . . . . . . . . . . . . . . 12-18 in. lbs.
Caution: A back-up wrench must be used to hold the bottom nut stationary.
Type 120 SPNO
Coil Coil Contact Rating (Amps) – Inductive Load
Model Duty Terminal Pole Bracket Voltage Resistance Contact Voltage Normally Open
Number Cycle Type Form Style D.C. (Ohms) Material D.C. Continuous Inrush
120-105711 Continuous 4 SPNO Standard 12 16.0
Silver Alloy 12 100 400
120-105851 Continuous 3A SPNO Standard 12 16.0
Silver Alloy 12 100 400
120-106131 Intermittent 4 SPNO Standard 12 6.0 Copper 12 80 400
120-106132 Intermittent 4 SPNO L 12 6.0 Copper 12 80 400
120-107112 Continuous 4 SPNO L 14 26.0
Silver Alloy 14 100 400
Intermittent Duty Cycle = 30 seconds “ON” maximum and 6 minutes “OFF”
“4” = Isolated Coil
Coil resistance in Ohms @ 25°C
Inrush Current: Current applied within the rst 1/2 second of contact closure
Coil grounded to bracket
NOTE: CAUTION must be used in coil selection for use in 12 volt
sytems where battery charging may expose coil to continuous,
higher-than-rated voltage. 14 volt coils are recommended.
White-Rodgers will not be responsible for consequences of misap-
plied solenoids.
SPNO
DC POWER
CONTACTORS
WARNING – FIRE HAZARD
Must be installed in a dry and protected
place. Failure to protect solenoid from water
and other contaminants could result in Fire,
Property Damage, Serious Personal Injury,
or Death.
Type 70 SPNO

Summary of content (1 pages)