Brochure

?
764 / 36C SERIES
GAS VALVES
GAS BURNER
CONTROLS
36C CYCLE PILOT GAS VALVES
With Redundant Pilot Solenoid Main Gas Regulator, Integral Gas
Pressure Switch and Electrical Connection on the Gas Valve for
Mercury Flame Sensor Connection.
SPECIFICATIONS
Electrical Rating . . . . . . . . . . . . . . . . . . . . 0.6 amps
End to End Dimensions . . . . . . . . . . . . . . 3
15
/
16
Ambient Operating Range . . . . . . . . . . . . -40 to +175°F (-40 to 79°C)
Maximum Pressure Rating . . . . . . . . . . . .
1
/
2
PSI (14.0 W.C.)
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . C.S.A. approved
PARTS AND ACCESSORIES See end of this section for parts and accessories
36C84-912
TECHNICAL HELP
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . See pages 171-174
STD. NAT GAS LP GAS STD. NAT GAS LP GAS
Pipe Size 1000 BTU/CU. FT. 2500 BTU/CU. FT. 1000 BTU/CU. FT. 2500 BTU/CU. FT.
1/2 X 3/8 100,000 162,000 15,000-100,000 15,000-162,000
1/2 X 1/2 230,000 372,600 30,000-290,000 30,000-469,000
1/2 X 3/4 230,000 372,600 30,000-290,000 30,000-469,000
3/4 X 3/4 280,000 453,600 50,000-400,000 50,000-648,000
1” Pressure Drop Capacity Rated Range of Regulation
BTU/HR BTU/HR
LP Internal
Regulator Conversion Reducer Inlet Wiring
Model Coil Gas Pipe Opening Regulator Adjustment Convertible Kit Line Flow Bushing Pressure Side See
Number Voltage Type Size Characteristic Setting Range Nat. / LP Included Interrupter Direction Kit Tap Taps Figure
36C84-912 24 VAC Nat./LP
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 Yes Yes No Str. Thru Yes Yes No 7
36C84-913 24 VAC Nat./LP
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 Yes Yes No Str. Thru Yes Yes No 12
36C84-921 24 VAC Nat./LP
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 Yes Yes No Str. Thru Yes Yes No 7
36C84-923 24 VAC Nat./LP
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 No No No Str. Thru No Yes No 14
36C84-926 24 VAC Natural
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 No No No Str. Thru Yes No No 4
36C84-945 24 VAC Nat./LP
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 Yes Yes No Str. Thru Yes Yes No 8
36C94-906 24 VAC Natural
3
/
4
x
3
/
4
Slow Open 3.5 2.5–5.0 No No No Str. Thru Yes No No 7
36C94-907 24 VAC Nat./LP
3
/
4
x
3
/
4
Slow Open 3.5 2.5–5.0 Yes Yes No Str. Thru Yes No No 4
Wiring diagrams – see pages 171-174 NOTE: -9XX series replaces -4XX series. Knob replaced with an ON-OFF switch.
PAGES
171-174
764 SERIES THERMOCOUPLE OPERATED
GAS PILOT SAFETY/GAS FIREPLACE VALVES
In Line Appliance Control with 100% Shut Off.
FEATURES / SPECIFICATIONS / PART AND ACCESSORIES
•Redesignedtoinclude100PSIprotection,inletscreenandinletpipestop.
•Optionalrearinlettappedandplugged.
•Maybemountedhorizontal,verticaland90°fromhorizontal(multipoise).
Electrical Rating . . . . . . . . . . . . . . . . . . . . 20 to 30 mV (Thermocouple)
RegulatorAdjustmentRange . . . . . . . . . . Non-regulated
Maximum Pressure Rating . . . . . . . . . . . .
1
/
2
PSI (14.0 W.C.)
Ambient Operating Range . . . . . . . . . . . . 32 to 175°F
Swing Radius . . . . . . . . . . . . . . . . . . . . . . 2.5
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . C.S.A. approved
764-702
•F42-0895—Replacementknob
Model Coil Inlet-Outlet Capacity A.G.A.
Number Voltage Size Standard Gas Electrical Connection
764-702 20 to 30 mV
3
/
8
x
3
/
8
132,000 Thermocouple
764-742 20 to 30 mV
1
/
2
x
1
/
2
142,000 Thermocouple
See page 414 for capacities of other gases