Installation Guide

Viewing System Status
Duringnormaloperation,theStatusscreendisplaysalltheinvertersettingsandoperationstatus.Scroll
upordowntodisplayvariousstatusparametersasdescribedinthefollowingsections.
TheLEDindicationprovidesmoreinformationaboutsystemperformance;RefertoLEDsonpage23.
To access the Status screen:
FromtheCommissioningmenuselectStatus.ThemaininverterStatusscreenisdisplayed(seebelow).
Aredororangeicon(forexample:
)mayappearatthetopleftcornerofastatuscell,indicatingan
error.Thecolorindicateserrorseverity(redistopseverity).Theerrordescriptionorinformationappears
onthescreen.Taptheerrorlineformoreinformationandtroubleshootinginstructions,andreferto
ErrorsandTroubleshootingonpage54.
Agrayclockicon(
)mayappearatthetopleftcornerofastatuscell,indicatingatemporarystatus,
suchasaconnectionprocess.Whentheprocessiscomplete,theicondisappearsandaconstantstatus
messageisdisplayed.
Main Inverter Status
Status
Inverter
SN 07318000C
Power
50 kW
Voltage
230Vac
Frequency
50 Hz
P_OK: 15 of 20
Optimizers Connected
Server Comm.
S_OK
(LAN)
Status
Production
Switch
OFF
CosPhi
1.00
Limit
No Limit
Country
USA2
Voltage
350 Vdc
Temp
156 F
Fan
Switch Off. Production disabled
Commissioning›
l Inverter:Theinverterserial number
l Power:TheACoutputpower
l Voltage (Vac):TheACoutputvoltage
l Frequency:TheACoutputfrequency
-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.0
38
Viewing System Status