Installation Guide

Technical Specifications - Single Phase Inverters with HD-Wave
Technology (North America)
SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Unit
OUTPUT
Rated AC Power Output 3000
3800 @ 240V
3300 @ 208V
5000
6000 @ 240V
5000 @ 208V
7600 10000 11400 VA
Max AC Power Output 3000
3800 @ 240V
3300 @ 208V
5000
6000 @ 240V
5000 @ 208V
7600 10000 11400 VA
AC Output Voltage
Min.-Nom.-Max.(183 - 208 - 229)
-
ü
-
ü
- - - Vac
AC Output Voltage
Min.-Nom.-Max.(211 - 240 - 264)
ü ü ü ü ü ü ü
Vac
AC Frequency (Nominal) 59.3 - 60 - 60.5
1
Hz
Maximum Continuous Output
Current 208V
- 16 - 25 - - - A
Maximum Continuous Output
Current 240V
12.5 16 21 25 32 42 47.5 A
Max. output fault current and
duration @208V
- 17.5 / 20 - 27.5 / 20 - - - A / ms
Max. output fault current and
duration @240V
14 / 20 17.5 / 20 23 / 20 27.5 / 20 40 / 20 56.6 / 20 A / ms
Inrush current AC (Peak/ Duration) 2.8 / 20 3.45 / 20
Aac
(rms) /
ms
Max. output overcurrent protection 35 48 55 80 A
1
For other regional settings please contact SolarEdge support
SolarEdge-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.0
63
Technical Specifications - Single Phase Inverters with HD-Wave Technology (North America)