WHYNTER 30 PINT RESIDENTIAL PORTABLE DEHUMIDIFIER Model # : RPD-302W INSTRUCTION MANUAL Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before using this product. Keep this manual in a safe place for future reference.
DISPOSAL INFORMATION Thank you for choosing the Whynter Portable Dehumidifier. Please follow the instructions provided in this user guide to obtain the very best performance from your dehumidifier. We trust that your Whynter dehumidifier will provide the performance and reliability that we stand for. Your Whynter dehumidifier is designed to remove moisture in the air by condensation removal and collecting the condensation water in the internal water bucket or draining through a drain hose.
TABLE OF CONTENTS PAGE DISPOSAL INFORMATION 2 I. SAFETY PRECAUTIONS 4 II. INTRODUCTION 5 III. PARTS AND CONTROLS 6 IV. OPERATION INSTRUCTIONS 7-8 V. CONTINUOUS DRAINAGE 9 VI. MAINTENANCE 10 VII. TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 11 VIII.
I. SAFETY PRECAUTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WHEN USING YOUR PORTABLE DEHUMIDIFIER, FOLLOW THESE BASIC PRECAUTIONS: Read all instructions before using the appliance Never clean appliance parts with flammable fluids. The fumes can create a fire hazard.
II. INTRODUCTION How it Works When the dehumidifier is started, the fan begins to pull moisture-laden air across the dehumidifying coils. The coils condense or draw moisture from the air, and air flows through the top louver into the room as dry, warm air. Moisture removed from air is collected in a water bucket on the front of the dehumidifier. The appliance is designed to operate between 41°F (5°C), and 96°F (35°C).
III. PARTS AND CONTROLS Set the desired time delay OFF hours by pressing the UP and DOWN and buttons. The time increments are 1 hour up to 24 hours. When the delay time set has elapsed, the appliance switches off. To cancel the delayed switch off function, set the time to “00” or turn off the appliance. Timer Delay Switch On When the appliance is OFF, press the Timer to activate Auto-start function and Timer light will come on. Set the desired time delay ON hours by pressing the UP and DOWN and buttons.
IV. OPERATION INSTRUCTIONS AIR FILTERS INSTALLATION Your Whynter portable dehumidifier is equipped with a removable and washable filter. The filter removes large particles such as dust, pet hair and dander. WARNING: NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER START OPERATION 1. Ensure that the appliance is connected to the power socket 2. Make sure the water bucket is placed in proper position. 3. Make sure filter is installed 4.
IV. OPERATION INSTRUCTIONS CASTER INSTALLATION Caster installation is recommended to avoid damage to floors . 1. Remove the casters from the bucket of the dehumidifier . 2. Position the dehumidifier on its side . 3. Locate the arrow on the bottom of the dehumidifier and insert the caster according to the arrow direction. 4. Slide the caster in as far as it will go. The caster will snap into place 5. Repeat steps 1 to 4 for the other 3 casters.
V. CONTINUOUS DRAINAGE GRAVITY METHOD This dehumidifier comes standard with a 3 ft. drain hose. To use gravity to drain your portable dehumidifier, it must be installed on a level surface or at least 12 inches above the ground, on a sturdy table or shelf unit. When using the function of continuous drainage, the hose must be placed horizontally below the drainage hole. Avoid uneven ground and folding the hose. 1. This appliance can be configured to avoid periodically manually emptying the water bucket.
VI. MAINTENANCE ALWAYS turn off and unplug the dehumidifier before cleaning. 1. Cleaning the air grille and main unit Use a damp cloth to wrap the main unit or use water and a mild detergent. Do not use bleach, chemicals or abrasives. Do not splash water directly onto the unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust. Use a vacuum attachment or brush to clean the air intake and outlet grilles 2.
VII. TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER If you have respiratory problems, asthma and allergies, your Whynter RPD-302W portable dehumidifier is a great option for controlling moist environments. Creating dry air can keep indoor air pollu- tants at a more manageable level, especially when used in conjunction with an air purifier.
VIII. TROUBLESHOOTING Problem The dehumidifier does not operate Possible Causes Power failure / outage. The automatic switch, line fuse, or breaker has been tripped. The power supply voltage is too low. The power cord is damaged. The dryness level you selected has been reached. Water bucket is full or not positioned properly. Solutions The dehumidifier runs too much The dehumidifier runs but the room is not dry enough.
VIII.
ONE YEAR LIMITED WARRANTY This WHYNTER portable dehumidifier is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service.