User manual

Unit 3: Interface Specifications
SATO MB2i Service Manual PN 9001145B Page 3-11
13. Open the SATO MB200i Configuration Tool screen (Figure 3-5) and enter as follows:
Select the Serial Port option for the interface type. Ensure COM1:19200,n,8,1
displays in the field to the right.
IP Address: to 150.100.100.1, then press the SET button.
Subnet Mask: to 255.255.255.0, then press the SET button.
Gateway: to 0.0.0.0, then press the SET button.
SSID: to MBPRINT, then press the SET button.
Channel Number: to 11, then press the SET button.
Operation Mode: to Ad-Hoc, then press the SET button.
Security Mode: to Disable WEP, then press the SET button.
Socket Port: to 9100, then press the SET button.
Figure 3-5, SATO MB200i Configuration Tool
14. Perform the following steps print a test label and verify the settings:
1. Power off the printer and change DSW2 to the ON position.
2 Press and hold the FEED button while powering on the printer. Release when indi-
cators are on.
3 Press the FEED button again to print a test label. Press FEED again to stop.
4 Ensure the contents of the label match those settings of step 13.
15. Ensure the contents of the label match those settings listed in step 13.
16. Repeat steps 2 through 15 if there is a discrepancy between the two.