User manual

Unit 5: Printer Configuration
SATO MB2i Service Manual PN 9001145B Page 5-2
PRINTER CONFIGURATION
The keys of the operator panel and dip switches are used either singularly or in conjuction to
perform configuration activities. The dip switch complex is accessible from the right housing
cover.
Refer to the Control Features chapter of the Introduction Unit for identification of specific
interface features.
FACTORY DEFAULTS
DSW1 DSW2 DSW3 DSW4
OFF OFF OFF OFF
RS232C QUICK REFERENCE TABLE
DESCRIPTION DIP SWITCHES HEAD PRINT KEY FEED KEY
Standard Start-Up OFF OFF OFF OFF Closed OFF OFF
User Test Print Closed OFF ON
Default Reset Opened ON OFF
Hex Dump OFF OFF ON ON Closed OFF OFF
Font Download OFF OFF OFF ON Closed OFF OFF
Dispense Auto Print Opened ON OFF
Dispense Manual Print Opened OFF OFF
Program Download OFF OFF ON OFF Closed OFF OFF
Factory Clear (w/o counter) Opened ON ON
Head Check OFF ON OFF ON Opened ON OFF
Cancel Head Check Opened OFF ON
Factory Clear (w’counter) OFF ON ON OFF Opened ON ON
IRDA QUICK REFERENCE TABLE
DESCRIPTION DIP SWITCHES HEAD PRINT KEY FEED KEY
Standard Start-Up ON OFF OFF OFF Closed OFF OFF
User Test Print Closed OFF ON
Hex Dump ON OFF ON ON Closed OFF
Head Check ON OFF OFF ON Opened ON OFF
Cancel Head Check Opened OFF ON
Factory Clear (w/counter) ON OFF ON OFF Opened ON ON
Online Command (MB200) ON ON ON ON Opened ON OFF
Online Command (SBPL) Opened OFF ON