User manual

Unit 7: Replacement Procedures
SATO MB2i Service Manual PN 9001145B Page 7-11
6 Insert the replacement eye-mark sensor to the inner cover and route the sensor harness
(Figure 7-8c).
Figure 7-8c, Eye-Mark Sensor Replacement
7 Secure the inner cover to the top housing cover using the two screws (Figure 7-8a).
8 Connect the sensor to the circuit board and route the wiring harness (Figure 7-8b).
9 Ensure the wiring harness has sufficient slack (Figure 7-8d).
Figure 7-8d, Eye-Mark Sensor Replacement
10 Reattach the top, left, and front housing covers.
NOTE: Figure 9-1 of the Charts & Diagrams unit provides guidance on
housing cover installation.
Sensor HarnessEye-Mark Sensor
Good
Not Good