User's Manual
Table Of Contents
- Contents
- Important Information
- Notices
- Description
- Installation
- Configuration
- Overview
- Accessing the Main Menu
- Configuring with the Main Menu
- Unit Identification
- Hardware/Software Revision
- System Software ROM Images
- System Current Status
- Network Configuration
- IP Filter Configuration
- RF Station Configuration
- Viewing Current RF Station Configuration
- Setting the Operating Mode
- General Equipment Setup for Performing RF Tests
- Setting Test Mode Timer Minutes
- Performing Link Monitor Test (Normal Mode)
- Performing Transmit and Receive Tests
- Performing the RSSI Test
- Setting the RF Transmit Status
- Setting the Link Monitor Period
- Setting Maximum Remote Distance (Base Station Only)
- Setting Link Monitor Remote Station Rank
- Adjusting Throttling (Remote Station Only)
- Setting Tx Power Automatically (Remote Station Only)
- Adjusting User Output Power Ceiling (Remote Station Only)
- Setting Signal Margin (Remote Station Only)
- Viewing Current Output Power Level Adjust
- Radio Module Configuration
- Viewing the Radio Module Configuration
- Setting Config Test Minutes
- Setting the Station Type
- Setting the Station Rank
- Setting the Center Frequency
- Setting Security Passwords
- Setting the Scrambling Code
- Setting the Acquisition Code
- Adjusting the Tx Power Level
- Setting a Base to Repeater Mode (Base Station Only)
- Setting System Symmetry Type (Base Station Only)
- Setting Dynamic Polling Level (Base Station Only)
- Setting Remote Unit RF Group
- Rebooting and Saving RF Module Configurations
- RF/Ethernet Statistics
- System Security
- System Commands
- Link Monitor Display
- Logout
- Setting Operating Mode with the Mode Button
- Command Line Interface
- Troubleshooting
- Appendix A: Planning Your Wireless Link
- Appendix B: Using HyperTerminal
- Appendix C: Configuring a Simple Data Network
- Appendix D: SNMP
- Appendix E: Technical Reference Information
- Appendix F: Menu Map
- Appendix G: Upgrading Software
- Glossary
- Index
Appendix D: SNMP
138 AWE 120-24 Installation & Configuration Guide
ipAddressFiltering 1.3.6.1.4.1.2686.2.1.16 INTEGER Read/Write IP address filtering:
0 = disabled, 1 = enabled
ipDefaultFiltering 1.3.6.1.4.1.2686.2.1.17 INTEGER Read/Write IP default filtering:
1 = pass, 2 = block
ipConfig 1.3.6.1.4.1.2686.2.1.18
ipFilter1Range 1.3.6.1.4.1.2686.2.1.18.1 INTEGER Read/Write IP address filter 1 range: 0-255
ipFilter1Base 1.3.6.1.4.1.2686.2.1.18.2 IpAddress Read/Write IP address filter 1 base address
ipFilter1State 1.3.6.1.4.1.2686.2.1.18.3 INTEGER Read/Write IP filter 1 state
0 = disabled, 1 = pass, 2 = block
ipFilter2Range 1.3.6.1.4.1.2686.2.1.18.4 INTEGER Read/Write IP address filter 2 range: 0-255
ipFilter2Base 1.3.6.1.4.1.2686.2.1.18.5 IpAddress Read/Write IP address filter 2 base address
ipFilter2State 1.3.6.1.4.1.2686.2.1.18.6 INTEGER Read/Write IP filter 2 state
0 = disabled, 1 = pass, 2 = block
ipFilter3Range 1.3.6.1.4.1.2686.2.1.18.7 INTEGER Read/Write IP address filter 3 range: 0-255
ipFilter3Base 1.3.6.1.4.1.2686.2.1.18.8 IpAddress Read/Write IP address filter 3 base address
ipFilter3State 1.3.6.1.4.1.2686.2.1.18.9 INTEGER Read/Write IP filter 3 state
0 = disabled, 1 = pass, 2 = block
ipFilter4Range 1.3.6.1.4.1.2686.2.1.18.10 INTEGER Read/Write IP address filter 4 range: 0-255
ipFilter4Base 1.3.6.1.4.1.2686.2.1.18.11 IpAddress Read/Write IP address filter 4 base address
ipFilter4State 1.3.6.1.4.1.2686.2.1.18.12 INTEGER Read/Write IP filter 4 state
0 = disabled, 1 = pass, 2 = block
ipFilter5Range 1.3.6.1.4.1.2686.2.1.18.13 INTEGER Read/Write IP address filter 5 range: 0-255
ipFilter5Base 1.3.6.1.4.1.2686.2.1.18.14 IpAddress Read/Write IP address filter 5 base address
ipFilter5State 1.3.6.1.4.1.2686.2.1.18.15 INTEGER Read/Write IP filter 5 state
0 = disabled, 1 = pass, 2 = block
Group Parameter Address/Node Syntax Access Description