User's Manual
Table Of Contents
- Contents
- Important Information
- Notices
- Description
- Installation
- Configuration
- Overview
- Accessing the Main Menu
- Configuring with the Main Menu
- Unit Identification
- Hardware/Software Revision
- System Software ROM Images
- System Current Status
- Network Configuration
- IP Filter Configuration
- RF Station Configuration
- Viewing Current RF Station Configuration
- Setting the Operating Mode
- General Equipment Setup for Performing RF Tests
- Setting Test Mode Timer Minutes
- Performing Link Monitor Test (Normal Mode)
- Performing Transmit and Receive Tests
- Performing the RSSI Test
- Setting the RF Transmit Status
- Setting the Link Monitor Period
- Setting Maximum Remote Distance (Base Station Only)
- Setting Link Monitor Remote Station Rank
- Adjusting Throttling (Remote Station Only)
- Setting Tx Power Automatically (Remote Station Only)
- Adjusting User Output Power Ceiling (Remote Station Only)
- Setting Signal Margin (Remote Station Only)
- Viewing Current Output Power Level Adjust
- Radio Module Configuration
- Viewing the Radio Module Configuration
- Setting Config Test Minutes
- Setting the Station Type
- Setting the Station Rank
- Setting the Center Frequency
- Setting Security Passwords
- Setting the Scrambling Code
- Setting the Acquisition Code
- Adjusting the Tx Power Level
- Setting a Base to Repeater Mode (Base Station Only)
- Setting System Symmetry Type (Base Station Only)
- Setting Dynamic Polling Level (Base Station Only)
- Setting Remote Unit RF Group
- Rebooting and Saving RF Module Configurations
- RF/Ethernet Statistics
- System Security
- System Commands
- Link Monitor Display
- Logout
- Setting Operating Mode with the Mode Button
- Command Line Interface
- Troubleshooting
- Appendix A: Planning Your Wireless Link
- Appendix B: Using HyperTerminal
- Appendix C: Configuring a Simple Data Network
- Appendix D: SNMP
- Appendix E: Technical Reference Information
- Appendix F: Menu Map
- Appendix G: Upgrading Software
- Glossary
- Index
Using Object Identifier Nodes
JUL 2001 Rev 03
139
ipFilter6Range 1.3.6.1.4.1.2686.2.1.18.16 INTEGER Read/Write IP address filter 6 range: 0-255
ipFilter6Base 1.3.6.1.4.1.2686.2.1.18.17 IpAddress Read/Write IP address filter 6 base address
ipFilter6State 1.3.6.1.4.1.2686.2.1.18.18 INTEGER Read/Write IP filter 6 state
0 = disabled, 1 = pass, 2 = block
ipFilter7Range 1.3.6.1.4.1.2686.2.1.18.19 INTEGER Read/Write IP address filter 7 range: 0-255
ipFilter7Base 1.3.6.1.4.1.2686.2.1.18.20 IpAddress Read/Write IP address filter 7 base address
ipFilter7State 1.3.6.1.4.1.2686.2.1.18.21 INTEGER Read/Write IP filter 7 state
0 = disabled, 1 = pass, 2 = block
ipFilter8Range 1.3.6.1.4.1.2686.2.1.18.22 INTEGER Read/Write IP address filter 8 range: 0-255
ipFilter8Base 1.3.6.1.4.1.2686.2.1.18.23 IpAddress Read/Write IP address filter 8 base address
ipFilter8State 1.3.6.1.4.1.2686.2.1.18.24 INTEGER Read/Write IP filter 8 state
0 = disabled, 1 = pass, 2 = block
config19 1.3.6.1.4.1.2686.2.1.19 INTEGER N/A Spare
config20 1.3.6.1.4.1.2686.2.1.20 INTEGER N/A Spare
config21 1.3.6.1.4.1.2686.2.1.21 INTEGER N/A Spare
config22 1.3.6.1.4.1.2686.2.1.22 INTEGER N/A Spare
config23 1.3.6.1.4.1.2686.2.1.23 INTEGER N/A Spare
config24 1.3.6.1.4.1.2686.2.1.24 INTEGER N/A Spare
config25 1.3.6.1.4.1.2686.2.1.25 INTEGER N/A Spare
config26 1.3.6.1.4.1.2686.2.1.26 INTEGER N/A Spare
macFilterEntryAge 1.3.6.1.4.1.2686.2.1.27 INTEGER Read/Write MAC Filter Entry Age Time Minutes: 1-60
outputPowerControl 1.3.6.1.4.1.2686.2.1.28 Nodes 28 to 28.4 are not available on units with S/W release 0.0.0
linkMonitorMode 1.3.6.1.4.1.2686.2.1.28.1 INTEGER Read/Write Link Monitor Mode
0 = normal, 1 = dynamic, 2 = auto
Group Parameter Address/Node Syntax Access Description