18 AWE 120-24 Installation & Configuration Guide
10. Select Logout to exit or press Esc.
Note: At this time you may want to finish configuring the base station according to the network
plan. See Configuration, page 29 for instructions about viewing and changing various settings.
Configuring a Remote Unit
When you configure a unit as a remote unit, you need to do the following tasks.
Check the Network Configuration information of the unit
Set the Station Type of the unit to "Remote Unit"
Assign the Station Rank (polling ID # of the remote unit)
Select a Center Frequency (must be the same for all units in network)
Select an Acquistion Code (must be the same for all units in network)
Set Tx Power Level Adjust intially to "0 dB"
Set the security passwords (must be the same for all units in network)
Change the default menu passwords
These tasks are described below in detail.
To configure a unit as a remote unit
1. Connect a PC to a AWE remote unit. Connect the COM port of the PC to the Serial port of the remote
unit using an adapter plug and RS-232 cable. See Configuring a Base Station, page 15 for cabling diagram.
2. Start the terminal emulation program (see Appendix B: Using HyperTerminal, page 127). Use the following
commnication settings: 9600 bps, 8 bits, no parity, 1 stop bit, no flow control.
3. Press
Enter. The AWE Login window is displayed. Type the default password supervisor and press
Enter. The Main Menu is displayed.
4. Select Network Configuration. Check the IP settings. If necessary, change the settings to match
the network plan.
5. From the Main Menu, select Radio Module Configuration and press
Enter. The Radio Module
Configuration window is displayed.