54 AWE 120-24 Installation & Configuration Guide
3. Select RF Station Configuration and press Enter. The RF Station Configuration menu is
displayed.
4. Select Operating Mode and press
Enter. The data field highlights.
5. Press the arrow keys to select Normal mode and press
Enter.
6. Select RF Transmit Status and press
Enter. The data field highlights.
7. Press the arrow keys to select unblocked and press
Enter.
8. Select Link Monitor Remote Station Rank and press
Enter. The data field highlights and the
remote automatically connects with the base station.
9. Select Link Monitor/Output Power and press
Enter. Set it to Normal.
10. Select Link Monitor Period and press
Enter. The data field highlights.
11. Type a link monitor period (1) and press
Enter. Link Monitor starts as soon as a non-zero value is
entered in the field. (A setting of 1 means that 50% of all data is test data.)
RF Station Configuration
Operating Mode -> Normal Mode
RF Transmit Status unblocked
Link Monitor Period (0=OFF, 1-10000) 0
Test Mode Timer Minutes (1-1000) 5
Base Station Only Parameters
Maximum Remote Distance 5 Km
Link Monitor Remote Station Rank 1
Remote Station Only Parameters
Throttle Enable off
Throttle Level (1-100) 10 (640 kps)
Link Monitor/Output Power Dynamic Output Power
User Output Power Adjust Ceiling -5 dB
Signal Margin (6-31) dB 6
Current Output Power Level Adjust -21